STEP 1 OUTLET CONNECTION

3.18 The horizontal outlet pipe must have a minimum fall of 1:100 (1

o

).

3.19 With 32 mm pipework fitted - the LS5 will pump a maximum horizontal distance

of 72 metres or a maximum vertical distance of 7 metres.

3.16 Ensure

that

the total flow drained at any given

time never exceeds the total pumped flow

from the unit, taking into account the height

and length of the outlet pipe. For instance,

- At 7 metres outlet head, the outlet flow is

30

l/min.

- At 2 metres outlet head, the outlet flow is

105

l/min.

3.17

Always ensure full access to the unit is possible for maintenance.