beautypg.com

Stuart Turner Showermate eco S2.0 bar Twin User Manual

Page 8

background image

- 8 -

Cont ...

Hot water connection:
2.29

Hot water cylinder or storage tank: When a hot water cylinder or storage tank

is used, ensure the pipework size from the cold water storage to the hot water

storage is of adequate size and a minimum of 22 mm for all models reducing

to 15 mm at the pump.

2.30

Hot water supply: The pump must be supplied with a dedicated feed direct

from the hot water cylinder or storage tank, ensuring an air free connection to the

cylinder, which can be made by one of the methods shown in Fig. 7. We

recommend the use of the Stuart flange TE Part No: 27800 for all models.

2.31

Expansion pipe: When the method of connection is to be made via the

expansion pipe, the

BASE of the cold water storage tank MUST be at least

1 metre above the connection/take off of the hot water storage cylinder feeding

the

pump.

Fig. 7

Off expansion
pipe with rising
28 mm offset
reducing to
22 mm pipework
to pump and
expansion pipe.

Off expansion
pipe with rising
22 mm offset
and 22 mm
pipework to
pump.

G 1 Stuart flange
top entry (TE)
(Part No. 27800)
with 22 mm
pipework to pump.

Factory installed G ¾
secondary tapping with
22 mm pipework to
pump.
or
Side mounted Stuart
flange side entry (SE)
(Part No. 27900) with
22 mm pipework to
pump.

This manual is related to the following products: