3.13
Pumps supplied with flexible inlet and outlet hoses:
Flexible pipes are supplied with this pump variant. The pump inlet and outlet
ports are threaded G ¾ male. These ports are provided with a flat sealing face
suitable for use with an appropriately sized flat faced fitting and fibre or rubber
washer. Ensure a watertight seal is achieved when the pump is both stationary
and
running.
1. Hoses incorporating integral
isolating valves should be
applied to the inlet side of
pump to satisfy servicing
requirements.
2. Standard hoses with no
integral isolating valve should
be applied to the outlet side of
pump.
3. Use correct tool for opening
and closing integrated
isolating valve to prevent
damage. Please note these
valves are of quarter turn
design, rotate clockwise to
close and anti-clockwise
to open. Failure to comply
to these instructions could
lead to valve damage.
Fig. 11
Close