beautypg.com

Stuart Turner Showermate eco S2.0 bar Twin User Manual

Page 12

background image

- 12 -

Cont ...

Fig. 12

22 mm Inlet pipework fed
from water storage system.

22 mm Copper
outlet pipework

Outlet

Outlet

Inlet

In the case of horizontal feeds use a 15 mm
compatible stem elbow (not supplied). Do not
bend the hose more than 30° as they may become
damaged, transmit noise or leak.

A typical alternative
outlet installation

22 x 15 mm Reducer

22 x 15 mm
Reducer

15 mm Copper pipe

15 mm Copper
pipe

22 mm Outlet pipework.

22 x 15 mm Reducer

22 mm Elbow

22 mm Copper pipe

15 mm Copper pipe

3.14

Typical Low Level Installation:

In certain installations it may be necessary to install a 90° bend on the inlet or

outlet connections of the pump before the flexible hose to accommodate a low

level

installation.

Below are some preferred connection options. All connections seal on the

pump body using a fibre or rubber sealing washer. Tap connector fittings should

be used which must be of an appropriate pressure and temperature rating.

It is essential when using any of the fittings shown below, that a correct

water tight seal is obtained between the pump body and selected fitting and also

the flexible hose and selected fitting. If in doubt contact the fitting manufacturer

and confirm compatibility with the connection to be sealed.

Carefully check connections and pipework for leaks whilst pump running and

stationary before leaving the installation unattended.

If you have any concern either about using push-in fittings or should the joint leak on
final test, isolate the water supplies and contact PumpAssist on 0844 98 000 97.