- 6 -

Cont ...

2.26

Non-Preferred Pump Location: The pump must be located with at least

0.5 metre flooded suction at all times.

If it is not possible to locate the pump in the preferred area due to site limitations

and it is necessary to position the unit in the loft, or in a position above the

secondary tapping that feeds the pump, then there is an increased risk of air

locks. This risk must be eliminated.

The following method will help to overcome the problem:

A “U” bend or downward loop in the supply pipe to the pump of 350 mm depth

before rising to the pump should ensure the cylinder vents its air up the

expansion pipe, not up the pump feed (Figs. 3 & 4).

2 LOCATION - SINGLE PUMP

Fig. 5

Static inlet pressure

Max. 10 m

Min. 0.5 m

Outlet head must be
below bottom of cold
water tank and able
to pass a minimum
of 0.8 l/min of gravity
flow

Fig. 3 (Twin Pump)

Fig. 4 (Single Pump)

Max. inlet head

10

m

Min. inlet head

0.5

m

Max. inlet head

10

m

Min. inlet head

0.5

m

hot water
services

hot water
services

least preferred area

least preferred area

200

mm

min

200

mm

min

350

mm

min

350

mm

min