Technical specification, Mechanical, Dimensions – Stuart Turner Monsoon Extra S3.0 bar Single User Manual
Page 15
![background image](/manuals/360713/15/background.png)
- 15 -
TECHNICAL SPECIFICATION
Stuart Turner reserve the right to amend the specification in line with its policy of
continuous development of its products.
Note:
For information on other voltages/frequencies which are not shown, consult
any supplementary instruction sheet supplied, or the rating label attached to
the
pump.
*Note: Max working pressure is the maximum pressure that can be applied to the
pump internal casing under any installation conditions.
**Note: In normal circumstances the temperature of stored water should never
exceed 65°C. A stored water temperature of 60°C is considered sufficient
to meet all normal requirements and will minimise deposition of scale in
hard water areas.
Maximum permissible water temperature 65°C.
Model
S1.4 bar
S3.0 bar
S3.5 bar
S4.5 bar
Electrical
Power supply
Volts/phase freqency
230/1/50
230/1/50
230/1/50
230/1/50
Enclosure
IPX4
IPX4
IPX4
IPX4
Type of motor
Induction
Induction
Induction
Induction
Power consumption
445 Watts
880 Watts
1135 Watts
1060 Watts
Full load current
2.0 Amps
3.9 Amps
5.2 Amps
4.9 Amps
Rating
Continuous (S1)
Continuous (S1)
Continuous (S1)
Continuous (S1)
Max. No Starts per hour
60
60
60
60
Mechanical
Max inlet head
10 metres
10 metres
10 metres
10 metres
Max head (closed valve)
14 metres
31 metres
32 metres
47 metres
Max working pressure*
500kPa (5.0 bar)
400 kPa (4.0 bar)
430 kPa (4.3 bar)
600 kPa (6.0 bar)
Max ambient air temperature
40
o
C
40
o
C
40
o
C
40
o
C
Max water temperature**
65
o
C
65
o
C
65
o
C
65
o
C
Min water temperature
4
o
C
4
o
C
4
o
C
4
o
C
Dimensions
Length
260 mm
344 mm
368 mm
443 mm
Width
133 mm
210 mm
210 mm
202 mm
Height (excluding flexible hoses)
249 mm
299 mm
299 mm
301 mm
Gross Weight (packed)
6.9 Kg
11.1 Kg
12.5 Kg
13.3 Kg
Cont ...