Stuart Turner Monsoon Extra S3.0 bar Single User Manual
Page 13

- 13 -
3. Priming
The pump must be primed (filled with water) before starting. Turn on water supply,
prime and vent the pump by unscrewing the priming plug (Figs. 17, 18 & 19) slowly
until all air escapes and water emerges. Re-tighten the plug.
4. Pre-Start
Check
Always ensure the pump is in a positive head position with flooded suction. A gravity
flow of one litre/min from the highest outlet is required to operate the integral flow
switch.
5. Starting
a) Switch on power and open terminal fitting. Pump should start and stop upon
demand.
b) Open and close all outlets in turn associated with the pump, (including w/c
systems) allowing water to flow from each outlet until all air is purged. As each
outlet is opened and closed, the pump will start and stop respectively.
c) Any tap or control valve within the system when opened and closed will now turn
the pump on/off. Check system for leaks, if clear the system is now operating
correctly.
d) Carefully check pump and pipework for leaks whilst pump running and stationary
before leaving the installation unattended.
For Further Technical Support
Phone the Stuart Turner Pump Assist team on 0844 98 000 97. Our staff are trained to
help and advise you over the phone or arrange for a service engineer to call.