Hot water connection:
(Applicable to S1.5, S2.0, S3.0 and S4.0 bar Twins, S2.0, S3.0 and S4.5 bar Singles)
2. 29
Hot water cylinder or storage tank: When a hot water cylinder or storage tank
is used, ensure the pipework size from the cold water storage to the hot water
storage is of adequate size and a minimum of 22 mm for all models except the
S4.5 bar twin which should be a minimum of 28 mm.
2.30
Hot water supply: The pump must be supplied with a dedicated feed direct
from the hot water cylinder or storage tank, ensuring an air free connection to the
cylinder, which can be made by one of the methods shown in Fig. 6 .
We
recommend the use of the Stuart flange top entry (TE) Part No 27800
(for all
models except the S4.5 bar Twin) (S4.5 bar Twin should only use ‘a’ or ‘d’).
2.31
Expansion pipe: When the method of connection is to be made via the
expansion pipe, the
BASE of the cold water storage tank MUST be at least
1 metre above the connection/take off of the hot water storage cylinder feeding
the
pump.
Fig. 6
a
b
c
d
Off expansion
pipe with rising
22 mm offset
and 22 mm
pipework to
pump.
Off expansion
pipe with rising
28 mm offset
reducing to
22 mm pipework
to pump and
expansion pipe.
G 1 Stuart flange
top entry (TE) (Part
No. 27800) with 22
mm pipework to
pump.
Factory installed G ¾
secondary tapping with
22 mm pipework to
pump.
or
Side mounted Stuart
flange side entry (SE)
(Part No. 27900) with
22 mm pipework to
pump.