7 technical specification (twin models), Mechanical, Pump dimensions – Stuart Turner Monsoon S1.5 bar Twin User Manual
Page 19

- 19 -
7 TECHNICAL
SPECIFICATION (Twin Models)
Model
S1.5 bar
Twin
S2.0 bar
Twin
S3.0 bar
Twin
S4.0 bar
Twin
S4.5 bar
Twin
Electrical
Power supply
Volts/phase freqency
230/1/50
230/1/50
230/1/50
230/1/50
230/1/50
Enclosure
IPX4
IPX4
IPX4
IPX4
IPX4
Type of motor
Induction
Induction
Induction
Induction
Induction
Power consumption
345 Watts
425 Watts
640 Watts
890 Watts
1090 Watts
Full load current
1.5 Amps
1.9 Amps
2.8 Amps
4.0 Amps
4.9 Amps
Rating
Continuous
(S1) @ 9 l/min
& above (Both
ends pumping)
Continuous
(S1) @ 9 l/min
& above (Both
ends pumping)
Continuous
(S1) @ 9 l/min
& above (Both
ends pumping)
Continuous
(S1) @ 9 l/min
& above (Both
ends pumping)
Continuous
(S1) @ 9 l/min
& above (Both
ends pumping)
Max. No Starts per hour
60
60
60
60
60
Mechanical
Max inlet head
14 metres
14 metres
14 metres
14 metres
14 metres
Max head (closed valve)
15 metres
20 metres
30 metres
42 metres
45 metres
Max working pressure*
600 kPa
(6.0 bar)
600 kPa
(6.0 bar)
600 kPa
(6.0 bar)
600 kPa
(6.0 bar)
600 kPa
(6.0 bar)
Max ambient air temperature
40
o
C
40
o
C
40
o
C
40
o
C
40
o
C
Max water temperature**
65
o
C
65
o
C
65
o
C
65
o
C
65
o
C
Min water temperature
4
o
C
4
o
C
4
o
C
4
o
C
4
o
C
P
ump
Dimensions
Length
265 mm
265 mm
265 mm
300 mm
310 mm
Width
126 mm
126 mm
126 mm
126 mm
126 mm
Height (excluding flexible hoses)
202 mm
202 mm
202 mm
202 mm
202 mm
Weight (incl. flexible hoses)
8.4 Kg
8.4 Kg
8.7 Kg
10.7 Kg
11.4 Kg
Pump connections:
Inlet
G ¾
G ¾
G ¾
G ¾
G ¾
Outlet
G ¾
G ¾
G ¾
G ¾
G ¾
Stuart Turner reserve the right to amend the specification in line with its policy of
continuous development of its products.
Note:
For information on other voltages/frequencies which are not shown, consult
any supplementary instruction sheet supplied, or the rating label attached to
the
pump.
*Note:
Max working pressure is the maximum pressure that can be applied to the
pump internal casing under any installation conditions.
**Note: In normal circumstances the temperature of stored water should never exceed
65°C. A stored water temperature of 60°C is considered sufficient to meet all
normal requirements and will minimise deposition of scale in hard water
areas.
Maximum permissible water temperature 65°C.
7.11
Noise: The equivalent continuous A-weighted sound pressure level at a distance
of 1 metre from the pump does not exceed 70 dB(A).