Stuart Turner Monsoon S1.5 bar Twin User Manual
Page 11

- 11 -
Cont ...
5. To break the joint, push pipe firmly into fitting, hold collet down and gently
remove pipe. If the system has been filled with water care should be taken to
isolate pump and towels used to absorb spilled water.
3.13
Typical Low Level Installation:
In certain installations it may be necessary to install a 90° bend on the inlet
or outlet connections of the pump before the flexible hose to accommodate a low
level
installation.
Below are some preferred connection options. All connections seal on the pump
body using a fibre or rubber sealing washer. Tap connector fittings should be
used which must be of an appropriate pressure and temperature rating.
It is essential when using any of the fittings shown below, that a correct water tight
seal is obtained between the pump body and selected fitting and also the
flexible hose and selected fitting. If in doubt contact the fitting manufacturer and
confirm compatibility with the connection to be sealed.
Carefully check connections and pipework for leaks whilst pump running and
stationary before leaving the installation unattended.
If you have any concern either about using push-in fittings or should the joint
leak on final test isolate the water supplies and contact PumpAssist on
0844 98 000 97.
Fig. 10
G ¾ female x 22 mm
elbow tap connector.
Fibre washer.
22 mm
elbow.
22 mm
copper
pipe
Fibre washer.
G ¾ female x 22 mm
tap connector.
22 mm compression to
G ¾ male.
22 mm copper pipe.
G ¾ female flexible hose
(supplied in kit).
22 mm compression to
G ¾ male.
G ¾ female flexible hose
(supplied in kit).
22 mm to G ¾
male.
G ¾ female
flexible hose
(supplied in
kit).
22 mm stem elbow.
G ¾ female x 22 mm tap
connector with rubber
sealing washer.
Sealing washer (sometimes
captured in fitting)
G ¾ female x 22 mm
swivel tap connector
with rubber sealing
washer.