XVI. UNIT NUMBER DESCRIPTION

SEPARATED COMBUSTION INDOOR MAKE-UP AIR UNITS

1, 2 - Unit Type [UT]

MS - Separated Combustion Indoor Make-up Air Unit

3, 4 - Capacity [CA]

*Single Furnace

Double Furnace

10 - 100,000 BTU/HR

50 - 500,000 BTU/HR.

15 - 150,000 BTU/HR

60 - 600,000 BTU/HR

20 - 200,000 BTU/HR

70 - 700,000 BTU/HR

25 - 250,000 BTU/HR

80 - 800,000 BTU/HR

30 - 300,000 BTU/HR
35 - 350,000 BTU/HR

Triple Furnace

40 - 400,000 BTU/HR

12 - 1,200,000 BTU/HR

*Single furnace capacities 10 through 40 are ETL certifi ed.

5 - Furnace Type [FT]

A - Standard Temperature Rise (20-60°F), Right Side Access
B - Standard Temperature Rise (20-60°F), Left Side Access
C - High Temperature Rise (60-90°F), Right Side Access
D - High Temperature Rise (60-90°F), Left Side Access
0 - None
Z - Other

6 - Furnace Construction Material [FM]

1 - Aluminized Steel
2 - 409 Stainless Steel (First Furnace Only)
3 - 409 Stainless Steel (All Furnace Sections)
4 - 321 Stainless Steel (First Furnace Only)
5 - 321 Stainless Steel (All Furnace Sections)
6 - 409 Stainless Steel Package (First Furnace Only)
7 - 409 Stainless Steel Package (All Furnace Sections)
8 - 321 Stainless Steel Package (First Furnace Only)
9 - 321 Stainless Steel Package (All Furnace Sections)
0 - None
Z - Other

7 - Indoor Arrangement

(includes furnace section(s)

[IA]

A - Duct Furnace (50-12 [CA] only)

K - Blower (High CFM) / Cooling

B - Blower (Standard)

0 - None

D - Blower (Standard) / Evap.

Z - Other

G - Blower (High CFM)

8 - Coil Options [CO]

A - DX Coil, 4 Row Single Circuit

E - Chilled Water Coil, 4 Row

B - DX Coil, 4 Row Dual Circuit

G - Chilled Water Coil, 6 Row

C - DX Coil, 6 Row Single Circuit

0 - None

D - DX Coil, 6 Row Dual Circuit

Z - Other

9 - Gas Type [GT]

1 - Natural Gas
2 - LP Gas (Propane)
3 - Natural Gas w/100% Shutoff
0 - None

10 - Gas Control [GC]

A - Single Stage Gas (Standard)
B - Two Stage Gas
H - Electronic Modulation w/Room Sensing
J - Electronic Modulation w/Duct Sensing
K - Electronic Modulation w/Duct Sensing & Ovrd. Stat
L - Electronic Modulation w/External 4-20 mA Input (Furnace One)
M - Electronic Modulation w/External 4-20 mA Input (All Furnaces)
N - Electronic Modulation w/External 0-10 VDC Input (Furnace One)
P - Electronic Modulation w/External 0-10 VDC Input (All Furnaces)
R - Two Stage Remote Temperature Control w/Duct Sensor
S - Three Stage Remote Temperature Control w/Duct Sensor
T - Four Stage Remote Temperature Control w/Duct Sensor
U - S-350 2 Stage Modular Electronic Control System
W - S-350 3 Stage Modular Electronic Control System
X - S-350 4 Stage Modular Electronic Control System
Y - S-350 6 Stage Modular Electronic Control System
0 - None
Z - Other

11 - Supply Voltage [SV]

1 - 115/1/60

5 - 230/3/60

2 - 208/1/60

6 - 460/3/60

3 - 230/1/60

7 - 575/3/60

4 - 208/3/60

0- None

Z - Other

12 - Motor Type [MT]

1 - Open Drip Proof (Standard)
2 - Totally Enclosed

3 - Premium Effi ciency, Open Drip Proof
4 - Premium Effi ciency, Totally Enclosed
0 - None
Z - Other

13 - Motor Sizes [MS]

A - 1/2 HP. w/Contactor

M - 1-1/2 HP. w/Mag. Starter

1 - 1 HP. VFD

B - 3/4 HP. w/Contactor

N - 2 HP. w/Mag. Starter

2 - 1-1/2 HP. VFD

C - 1 HP. w/Contactor

P - 3 HP. w/Mag. Starter

3 - 2 HP. VFD

D - 1-1/2 HP. w/Contactor

R - 5 HP. w/Mag. Starter

4 - 3 HP. VFD

E - 2 HP. w/Contactor

S - 7-1/2 HP. w/Mag. Starter

5 - 5 HP. VFD

G - 3 HP. w/Contactor

T - 10 HP. w/Mag. Starter

6 - 7-1/2 HP. VFD

H - 5 HP. w/Contactor

U - 15 HP. w/Mag. Starter

7 - 10 HP. VFD

J - 1/2 HP. w/Mag. Starter

0 - None

8 - 15 HP. VFD

K - 3/4 HP. w/Mag. Starter

Z - Other

L - 1 HP. w/Mag. Starter

14 - Air Inlet Confi guration [AI]

1 - Outside Air (OA)

4 - Outside Air and Return Air (OA/RA)

2 - Outside Air w/Air Hood*

5 - Outside and Return Air w/Air Hood*

3 - Return Air (RA)

0 - None

Z - Other

15 - Air Control & Damper Arrangement [AC]

A - Outside Air 2 Pos. Motor / Spring Return
B - Return Air 2 Pos. Motor / Spring Return
C - OA/RA 2 Pos. / Spring Return
D - OA/RA Mod. Mtr. w/Mixed Air Control / Min. Pot.
E - OA/RA Mod. Mtr. w/Mixed Air Control / Min. Pot. / SR
G - OA/RA Mod. Mtr. w/Mixed Air Control
H - OA/RA Mod. Mtr. w/Mixed Air Control / SR
J - OA/RA Mod. Mtr. w/Min. Pot.
K - OA/RA Mod. Mtr. w/Min. Pot. / SR
L - OA/RA Mod. Mtr. w/Dry Bulb / Mixed Air Control / Min. Pot.
M - OA/RA Mod. Mtr. w/Dry Bulb / Mixed Air Control / Min. Pot. / SR
N - OA/RA Mod. Mtr. w/Enthalpy Controlled Economizer / SR
P - OA/RA Mod. Mtr. w/Pressure Control (Space Pressure)
Q - OA/RA Mod. Mtr. w/Carbon Dioxide (CO

2

) R/A Monitor

R - OA/RA Mod. Mtr. w/S-350-P Proportional Mixed Air Control / SR
S - OA/RA Mod. Mtr. w/0-10 VDC & 4-20 mA Analog Input (External Input)
T - OA/RA Mod. Mtr. w/0-10 VDC & 4-20 mA Analog Input / SR (External Input)
U - ASHRAE Cycle I (OA/RA 2 Pos. Mtr. w/Warm-up Stat / SR)
W - ASHRAE Cycle II (OA/RA Mod. Mtr. w/Warm-up Stat / Mixed Air / Min. Pot. / SR)
X - ASHRAE Cycle III (OA/RA Mod. Mtr. w/Warm-up Stat / Mixed Air / SR)
Y - Manual Dampers
0 - None

MOD = Modulating Damper Motor

Z - Other

OA = Outside Air RA = Return Air SR = Spring Return

16 - Accessories [AS]

A1 - Moisture Eliminators

H1 - Return Firestat

A2 - Horizontal Return

H2 - Supply Firestat

A3 - Low Leak Damper

H3 - Freezestat w/Time Delay

A6 - High Altitude Unit

H4 - Ambient Lockout

A7 - High Pressure Regulator
A8 - Unit Derate

J1 - Interlock Relay - 24V Coil DPDT 10A, Plug-in

J2 - Interlock Relay - 24/115V Coil SPDT 10A

B1 - Filters - 1" WA (Standard)

J3 - Interlock Relay - 24/115/230V Coil DPDT 10A

B2 - Filters - 2" WA

J4 - Interlock Relay - 24V Coil 4PDT 10A

B3 - Filters - 2" TA
B4 - Filters - 1" 30%

K1 - Manual Reset High Limit Switch

B5 - Filters - 2" 30%

K2 - High / Low Gas Pressure Limit Switches

K3 - Status Lamp (Elec. Cabinet)

C1 - Evap. Cooler - Fill & Drain Kit

K4 - Fan Time Delay (Arrangement “A” Only)

C2 - Evap. Cooler - 12" CELdek

®

Media

K5 - Air Flow Prove Switch (Dwyer 1910-0)

C3 - Evap. Cooler - Freezestat
w/o Time Delay

L1 - 30 Amp, Fused Disconnect Switch

C4 - Evap. Cooler - 8" GLASdek

®

Media

L2 - 30 Amp, Non-fused Disconnect Switch

C5 - Evap. Cooler - 12" GLASdek

®

Media

L3 - 60 Amp, Fused Disconnect Switch

L4 - 60 Amp, Non-fuse Disconnect Switch

D1 - Time Clock - 7 Day
D2 - Time Clock - 24 Hour

M2 - Vent Caps

M3 - Adaptor(s) (4"-5" inches)

E1 - Clogged Filter Switch

M4 - Vertical Concentric Vent Kit

E2 - G.F.I. Convenience Outlet 115VAC

M5 - Horizontal Concentric Vent Kit

E3 - Remote Control Panel

E4 - Manual Blower Switch

N5 - Service Convenience Package

N6 - Double Wall Construction

F1 - Ductstat - One Stage
F2 - Ductstat - Two Stage

R1 - Field Installed VFD

R2 - Factory Installed VFD

G1 - Thermostat - T87K w/Subbase

R3 - VFD Remote Keypad for use w/R1

G2 - Thermostat - T87K w/Subbase & Guard R4 - CO

2

Sensor - 100% OA

G3 - Thermostat - T834N w/Subbase (Sterling Stat) R5 - CO

2

Sensor - Mixed Air

G4 - Thermostat - TB8220U - 7 Day Programmable R6 - Pressure Sensor
G5 - Thermostat - TH5220D (Two Stage)

R7 - 2-Speed VFD Relays

G6 - Locking Thermostat Cover

R8 - 3-Speed VFD Relays

Note: All thermostats are Mercury free

0 - None

Z1- Other (Specify)


† = Field Installed
*Single furnace capacities 10 through 40 are ETL certifi ed.