33 — dimensional data — arrangements, Typical intake air end view, Typical discharge end view – Sterling MS User Manual
Page 33

— 33 —
DIMENSIONAL DATA — ARRANGEMENTS
This tabulated dimensional data applies to all dimensional drawings.
Typical
Intake Air End View
(Not applicable to [IA]-A or D
See Evaporative Cooling Specifi cations)
Typical
Discharge End View
***Capacity
Gas
Inlet
(CA)
A B C D G H J
▲
L U
V
Dia.**
NAT
LP
10
32- 7/8
15- 9/16
16- 7/8
19- 3/8
30- 3/16
37-1/16
24
N/A
N/A
4
1/2
1/2
(835) (395) (418) (492) (767) (640) (610)
(102)
15
32- 7/8
18- 5/16
16- 7/8
19- 3/8
30- 3/16
37- 1/16
24
N/A
N/A
4
1/2
1/2
(835) (465) (418) (492) (767) (640) (610)
(102
20
43- 7/8
23- 13/16
21- 15/16
24- 7/8
41- 3/16
37- 7/16
35
N/A
N/A
5
1/2
1/2
(1114) (605) (557) (632) (1046) (678) (889)
(127)
25
43- 7/8
29- 5/16
21- 15/16
24- 7/8
41- 3/16
37- 7/16
35
N/A
N/A
5
3/4
1/2 OR 3/4
(114) (745) (557) (632) (1046) (678) (889)
(127)
30
54- 7/8
34- 13/16
27- 7/16
30-3/8
52- 3/16
36- 11/16
46
N/A
N/A
6
3/4
1/2 OR 3/4
(1394) (884) (697) (772) (1326) (640) (1168)
(152)
40
60- 3/8
45- 13/16
30- 3/16
33- 3/16
57- 11/16
36- 11/16
51- 1/2
N/A
N/A
6
3/4
1/2 OR 3/4
(1534) (1164) (767) (841) (1465) (640) (1308)
(152)
50
43- 7/8
29- 5/16
21- 15/16
24- 7/8
42- 1/16
37- 7/16
35
N/A
N/A
5
3/4
1/2 OR 3/4
(114) (745) (557) (632) (1068) (678) (889)
(127)
60
54- 7/8
34- 13/16
27- 7/16
30- 3/8
53- 1/16
36- 11/16
46
N/A
N/A
6
3/4
1/2 OR 3/4
(1394) (884) (697) (772) (1348) (640) (1168)
(152
70
54- 7/8
40-5/16
27- 7/16
30- 3/8
53- 1/16
36- 11/16
46
N/A
N/A
6
3/4
1/2 OR 3/4
(1394) (1024) (697) (772) (1348) (640) (1168)
(152
80
60- 3/8
45- 13/16
30- 3/16
33- 1/8
58- 9/16
36- 11/16
51- 1/2
181-1/4
177
6
3/4
1/2 OR 3/4
(1534) (1164) (767) (841) (1487) (932) (1308) (4604) (4495) (152)
12
60- 3/8
45- 13/16
30- 3/16
33- 1/8
58- 9/16
36- 11/16
51- 1/2
218-1/4
217
6
3/4
1/2 OR 3/4
(1534) (1164) (767) (841) (1487) (932) (1308) (5544) (5512) (152)
NOTES: Unless otherwise noted the end views and dimensional data shown in the drawings and table are applicable to Indoor Arrangement [IA]-B, D, G, K.
Dimensions are in inches. Dimensions in parenthesis are in millimeters.
J
▲
Dimension is an outside dimension for the return air damper.
*This is an outside damper dimension.
**V = Flue Opening; the 4" to 5" reducer adaptor is to be fi eld installed for unit capacities 10 & 15.
The 5" to 6" increaser adaptor is supplied by the manufacturer for unit capacities 30, 35, 40, 60, 70, 80 & 12 (required for each furnace's fl ue).
***Capacities 10 through 40 are ETL certfi ed.