beautypg.com

33 — dimensional data — arrangements, Typical intake air end view, Typical discharge end view – Sterling MS User Manual

Page 33

background image

— 33 —

DIMENSIONAL DATA — ARRANGEMENTS

This tabulated dimensional data applies to all dimensional drawings.

Typical

Intake Air End View

(Not applicable to [IA]-A or D

See Evaporative Cooling Specifi cations)

Typical

Discharge End View

***Capacity

Gas

Inlet

(CA)

A B C D G H J

L U

V

Dia.**

NAT

LP

10

32- 7/8

15- 9/16

16- 7/8

19- 3/8

30- 3/16

37-1/16

24

N/A

N/A

4

1/2

1/2

(835) (395) (418) (492) (767) (640) (610)

(102)

15

32- 7/8

18- 5/16

16- 7/8

19- 3/8

30- 3/16

37- 1/16

24

N/A

N/A

4

1/2

1/2

(835) (465) (418) (492) (767) (640) (610)

(102

20

43- 7/8

23- 13/16

21- 15/16

24- 7/8

41- 3/16

37- 7/16

35

N/A

N/A

5

1/2

1/2

(1114) (605) (557) (632) (1046) (678) (889)

(127)

25

43- 7/8

29- 5/16

21- 15/16

24- 7/8

41- 3/16

37- 7/16

35

N/A

N/A

5

3/4

1/2 OR 3/4

(114) (745) (557) (632) (1046) (678) (889)

(127)

30

54- 7/8

34- 13/16

27- 7/16

30-3/8

52- 3/16

36- 11/16

46

N/A

N/A

6

3/4

1/2 OR 3/4

(1394) (884) (697) (772) (1326) (640) (1168)

(152)

40

60- 3/8

45- 13/16

30- 3/16

33- 3/16

57- 11/16

36- 11/16

51- 1/2

N/A

N/A

6

3/4

1/2 OR 3/4

(1534) (1164) (767) (841) (1465) (640) (1308)

(152)

50

43- 7/8

29- 5/16

21- 15/16

24- 7/8

42- 1/16

37- 7/16

35

N/A

N/A

5

3/4

1/2 OR 3/4

(114) (745) (557) (632) (1068) (678) (889)

(127)

60

54- 7/8

34- 13/16

27- 7/16

30- 3/8

53- 1/16

36- 11/16

46

N/A

N/A

6

3/4

1/2 OR 3/4

(1394) (884) (697) (772) (1348) (640) (1168)

(152

70

54- 7/8

40-5/16

27- 7/16

30- 3/8

53- 1/16

36- 11/16

46

N/A

N/A

6

3/4

1/2 OR 3/4

(1394) (1024) (697) (772) (1348) (640) (1168)

(152

80

60- 3/8

45- 13/16

30- 3/16

33- 1/8

58- 9/16

36- 11/16

51- 1/2

181-1/4

177

6

3/4

1/2 OR 3/4

(1534) (1164) (767) (841) (1487) (932) (1308) (4604) (4495) (152)

12

60- 3/8

45- 13/16

30- 3/16

33- 1/8

58- 9/16

36- 11/16

51- 1/2

218-1/4

217

6

3/4

1/2 OR 3/4

(1534) (1164) (767) (841) (1487) (932) (1308) (5544) (5512) (152)

NOTES: Unless otherwise noted the end views and dimensional data shown in the drawings and table are applicable to Indoor Arrangement [IA]-B, D, G, K.

Dimensions are in inches. Dimensions in parenthesis are in millimeters.

J

Dimension is an outside dimension for the return air damper.

*This is an outside damper dimension.

**V = Flue Opening; the 4" to 5" reducer adaptor is to be fi eld installed for unit capacities 10 & 15.

The 5" to 6" increaser adaptor is supplied by the manufacturer for unit capacities 30, 35, 40, 60, 70, 80 & 12 (required for each furnace's fl ue).

***Capacities 10 through 40 are ETL certfi ed.