beautypg.com

4 test procedures, Insulation resistance, Protective grounding – Yokogawa Removable Chassis DX1000N User Manual

Page 18: 4 test procedures -4, Insulation resistance -4 protective grounding -4, Test procedures

background image

3-4

SM 04L41B01-01E

3.4 Test Procedures

Insulation Resistance

● Test Procedures

Perform a measurement with an insulation resistance meter and check whether the

results satisfy the reference values. Perform the measurement with the power switch
turned ON.

Reference Value

Terminals Measured

Reference Value

Condition

Between the power and protective ground

terminal

100 MΩ or more

Short the L and N terminals.

Between the input and protective ground

terminal

100 MΩ or more

Short all input terminals.

Between the Ethernet and protective

ground terminal

100 MΩ or more

Short all pins of the Ethernet
terminal.

Between RS-422/485 SG and

RS-422/485 FG terminals

100 MΩ or more

With the /C3 option.

Protective Grounding

● Test Procedures

Perform a resistance measurement with a DMM (digital multimeter), and check

whether the results satisfy the reference values.

Reference Value

Measured Location

Reference Value

Between the protective ground terminal

and bezel attachment screw (left side)

0.2 Ω or less

USB

CF CARD

NO.

Do not remove the cover.

Repair by trained personnel only.

Protective ground terminal

DX1000/DX1000N

Bezel attachment screw (left side)

DX2000

POWER

CF CARD

USB

Bezel attachment screw (left side)

Protective ground terminal