Changes to how the data files are named – Yokogawa Removable Chassis DX1000N User Manual
Page 10
10
IM 04L41B01-03E
Resetting the Computed Value during Computation (/M1 and /PM1 Options)
You can reset the computed value not only when the computation is stopped but also
when the computation is in progress.
Section 9.4, “Starting/Stopping Computation, Resetting Computation, and Releasing
Computation Data Dropout Display” in the user’s manual
Changes to How the Data Files Are Named
The table below shows the file name that is assigned when the measured data is saved
to the CF card.
Differences from the File Names up to Now
• The “ID” item at the end of the file name is deleted and its functionality is included in
the “Separator” of the 7-digit sequence.
• The sequence section of the display data and event data file names is changed to
7 digits, and the “ID” function is included in the “Separator” when using the “Batch
name.”
Date
Sequence
Batch name
Display data
Event data
Manual sampled data
Snapshot data
Report data
Display data
Event data
Manual sampled data
Snapshot data
Report data
.
.
.
.
.
.
Display data
Event data
Report data
Manual sampled data
Snapshot data
.
Specified string
Date
Date
Type
Type
Type
Date
Extension
Extension
Extension
Extension
Extension
Extension
Extension
Date
Specified string
Specified string
Specified string
Batch name
Ex.: 000123_AAAAAAAAAAA050928_174633.DAD
Ex.: 000123_AAAAAAAAAAA.DAD
Ex.: 000123_AAAAAAAAAAA0HD.DAR
Ex.: 000123_BBBBBBBBBBBBBBBBBBBBB.DAD
Ex.: 000123_050928_174633HD.DAR
Ex.: 000123_050928_174633.DAM
Ex.: 000123_AAAAAAAAAAA050928_174633HD.DAR
Item
Date
YYMMDD_HHMiSS
YY: Year (lower two digits), MM: Month, DD: Day
HH: Hour, Mi: Minute, SS: Second
Specified string AAAAAAAAA•••A
Up to 16 alphanumeric characters can be used
Batch name
BBBBBBBBBBB•••B Up to 40 alphanumeric characters can be used
7-digit sequence 000001~999999
Consists of a 6-digit number and a separator. The number is
assigned in order of occurrence.
When the 6-digit number reaches 999999, it returns to 000000.
The separator starts with an underscore followed by a character
that changes in the following order: A to Z and then 0 to 9.
Description
Structure
Description
Display data
:DAD
Event data
:DAE
Manual sampled data
:DAM
Type
Report data type
H_: Hourly, D_: Daily, W_: Weekly, M_: Monthly,
HD: Hourly and daily, DW: Daily and weekly,
DM: Daily and monthly
H_, D_, W_, M_,
HD, DW, DM
Extension
Report data
:DAR
Snapshot data
:PNG
Setup data
:PDL
7-digit
7-digit
7-digit
7-digit
7-digit
7-digit
7-digit
Operations on the DX1000/DX1000N/DX2000