Accessories, Model and suffix code – Yokogawa ADMAG AXF User Manual
Page 106

IM 01E20C01-01E
11-5
11. OUTLINE
Vibration Conditions:
Level of vibration in conformity with IEC 60068-2-6
(SAMA31. 1-1980)
4.9 m/s
2
G or less (frequency of 500 Hz or less)
Note: Avoid locations with much vibration (with a vibration
frequency of 500 Hz or more), which may cause
damage to the equipment.
■ ACCESSORIES
Mounting bracket: 1 set
■ MODEL AND SUFFIX CODE
AXFA11 Magnetic Flowmeter Remote Converter:
Model
Suffix Code
Description
AXFA11
Use
Output Signal
and
Communication
Power Supply
Electrical
Connections
Indicator
Option
Magnetic Flowmeter Remote Converter
General-Purpose Use
For AXF Remote Flowtube of size
2.5 to 2600 mm (0.1 in. to 104 in.)
4 to 20 mA DC,
BRAIN Communication
4 to 20 mA DC,
HART Communication
100 V to 240 V AC or
100 to 120 V DC
24 V AC/DC
(*1)
JIS G1/2 female
ANSI 1/2 NPT female
ISO M20
ϫ 1.5 female
With Indicator
Optional code (See the Table of
Optional Specifications)
G · · · · · · · · · · · · ·
-D · · · · · · · · · ·
-E · · · · · · · · · ·
1 · · · · · · · ·
2 · · · · · · · ·
-0 · · · · · ·
-2 · · · · · ·
-4 · · · · · ·
1 · · · ·
/
ٗ
T03.EPS
*1: In case of power supply code 2 (24 V AC/DC), optional
code A (lighting protector) is mandatory.
Signal Cable:
Model
Suffix Code
Description
AXFC
Termination
Cable
Length
Option
Magnetic Flowmeter
Dedicated Signal cable for the
ADMAG AXF series
No Termination. A set of termination
parts for M4 screws is attached.
Terminated for the AXFA11/14
Converter.
Designate the cable length, unit: m
Following “L”, specify the cable in
three digits as multiple of 1 meter
(e.g., 001, 002, or 005)
for a length up to 5 m, or as
a multiple of 5 meters (i.e., 005,
010, 015, or the like).
The maximum cable length:
200 m for combined use with AXFA11
100 m for combined use with AXFA14
With termination parts sets.
Following “C”, specify the q’ty of sets
of termination parts in one digits.
· · · · · · · · · · · · ·
-0 · · · · · · · · · · ·
-4 · · · · · · · · · · ·
-L
ٗٗٗ · · · ·
/C
ٗ
T04.EPS
Note: • The cable is constructed with double shielding
over the two conductors, and uses heat-resistant
vinyl as the outer covering material.
Finished diameter: 10.5 mm (0.413 in.)
Maximum temperature: +80˚C (+176˚F)
• Unnecessary to order the above cable for
submersible type flowtube or for the optional code
DHC flowtube because the flowtube is wired with
30 m (98 ft) cable.
• For excitation cable, prepare a two-core cable at
the customer side.