Page 44: Device information, Table 7.9 alarm summary

background image

IM 01E20F02-01E

7-4

7. DEVICE INFORMATION

7.2 Status of each parameter in

failure mode

Following tables summarize the value of AXF
parameters and LCD display indicates an Alarm.

Table 7.9

Alarm Summary

T0708.EPS

10:uP Fault

200

Other

Hold

BAD:Device Failure

11:EEPROM Fault

199

Other

Hold

BAD:Device Failure

12:A/D (H) Fault

198

Other

Hold

BAD:Device Failure

13:A/D (L) Fault

197

Other

Hold

BAD:Device Failure

14:A/D (Z) Fault

196

Other

Hold

BAD:Device Failure

15:Coil Open

195

Other

Hold

BAD:Sensor Failure

16:EEPROM Dflt

194

Other

Hold

BAD:Device Failure

100:Comm uP Fault

190

Other

Variable BAD:Device Failure

101:Comm EEPROM Fault

189

Other

Variable BAD:Device Failure

102:IT1 Not Saved

-

103:IT2 Not Saved

-

104:Comm Error1

188

Other

Variable BAD:Device Failure

105:Comm Error2

187

Other

Variable BAD:Device Failure

106:DL Incomplete

-

107:Download Fail

-

108:Not Ready

-

30:Sig Overflow

170

Other

Hold

BAD:Sensor Failure

31:Empty Pipe

169

Other

Hold

BAD:Sensor Failure

33:Adhesion Alm

167

Other

Hold

BAD:Sensor Failure

110:AI Lo Lo Alm

-

111:AI Hi Hi Alm

-

112:PID Lo Lo Alm

-

113:PID Hi Hi Alm

-

40:RS O/S Mode

BAD:Non-specific

41:TB O/S Mode

Out of

BAD:Out of Service

Service

42:AI FB O/S Mode

-

43:IT1 FB O/S Mode

-

44:IT2 FB O/S Mode

-

45:DI1 FB O/S Mode

-

46:DI2 FB O/S Mode

-

47:AR FB O/S Mode

-

48:PID FB O/S Mode

-

50:Span > 10m/s

160

Other

Hold

BAD:Configuration

Error

51:Span < 0.1m/s

159

Other

Hold

BAD:Configuration

Error

57:Dens Set Err

157

Other

Hold

BAD:Configuration

Error

71:Meas Mod Set

156

Other

Hold

BAD:Configuration

Error

72:Size Set Err

155

Other

Hold

BAD:Configuration

Error

73:Adh Set Err

154

Other

Hold

BAD:Configuration

Error

120:IT1 Clock Per Err

-

121:IT2 Clock Per Err

-

122:AR Range Set Err

-

Category

Alarm

XD_

ERROR

(Value)

BLOCK_

ERROR

Primary

Value

Primary Value

Status

System
Alarms

Process
Alarms

O/S
Mode
Alarms

Setting
Alarms

80:Adhesion Wng

150

Other

Uncertain:Sensor

Conversion not

Accurate

82:Auto Zero Wng

148

Other

Uncertain:Sensor

Conversion not

Accurate

84:Disp Over Wng

-

85:Flow Vel Over

147

Other

Uncertain: Engineering

Unit Range

Violation

130:AI Non-Schedule

-

131:IT1 Non-Schedule

-

132:IT2 Non-Schedule

-

133:DI1 Non-Schedule

-

134:DI2 Non-Schedule

-

135:AR Non-Schedule

-

136:PID Non-Schedule

-

140:Sim. Jmpr On

-

141:AI Sim. Enabled

-

142:DI1 Sim. Enabled

-

143:DI2 Sim. Enabled

-

150:AI FB Man Mode

-

151:IT1 FB Man Mode

-

152:IT2 FB Man Mode

-

153:DI1 FB Man Mode

-

154:DI2 FB Man Mode

-

155:AR FB Man Mode

-

156:PID FB Man Mode

-

160:PID FB Bypass Mode

-

Category

Alarm

XD_

ERROR

(Value)

BLOCK_

ERROR

Primary

Value

Primary Value

Status

Warning

This manual is related to the following products: