background image

<9. General Specifications>

9-3

IM 01C25F01-01E

Atmospheric

pressure

-40

(-40)

0

(32)

40

(104)

80

(176)

120

(248)

1(0.14)

2.7(0.38)

10(1.4)

(psia)

100(14.5)

Process temperature °C (°F)

Working

pressure

kPa abs

Applicable range

F0902.ai

Figure 9.2

Working Pressure and Process

Temperature [For EJ530 and

EJX630A]

Maximum Over Pressure

Pressure

Capsule

EJ510

EJ530

A and B 4 MPa abs (580 psia)

4 MPa (580 psig)

C

20 MPa abs (2900 psia)

20 MPa (2900 psig)

D*

75 MPa abs (10800 psia) 75 MPa (10800 psig)

*: 60 MPa (8700 psi) for EJA510E and EJA530E.

Pressure

Capsule

EJX610A

EJX630A

A

4 MPa abs (580 psia)

4 MPa (580 psi)

B

16 MPa abs (2300 psia) 16 MPa (2300 psi)

C

25 MPa abs (3600 psia) 25 MPa (3600 psi)

D

105 MPa abs (15200 psia) 105 MPa (15200 psi)

Supply & Load Requirements “◊”

(Optional features or approval codes may

affect electrical requirements.)

With 24 V DC supply, up to a 550 Ω load can be

used. See graph below.

E-10.5

0.0244

(Ω)

Power supply voltage E (V DC)

600

250

R

10.5

16.6

25.2

42

External

load

resistance

Digital

Communication

range

BRAIN and HART

R=

F0903.ai

Figure 9.3

Relationship Between Power Supply

Voltage and External Load Resistance

Supply Voltage “◊”

10.5 to 42 V DC for general use and flameproof

type.

10.5 to 32 V DC for lightning protector (Option

code /A).

10.5 to 30 V DC for intrinsically safe, type n or

non-incendive type.

Minimum voltage limited at 16.6 V DC for digital

communications, BRAIN and HART

Load (Output signal code D, E and J)

0 to 1290 Ω for operation

250 to 600 Ω for digital communication