2 wiring, 1 connecting the power cord, 2 wiring -7 – Proface FP3900 - 19 Flat Panel" User Manual
Page 52: 1 connecting the power cord -7, 7 5.2 wiring
![background image](/manuals/358993/52/background.png)
Chapter 5 Installation and Wiring
5-7
5.2
Wiring
5.2.1
Connecting the Power Cord
FP-3710K Series
Power Cable specification
Use copper conductors only.
To avoid an electric shock, when connecting the FP’s power cord terminals to the power
terminal block, confirm that the FP’s power supply is completely turned OFF, via a breaker,
or similar unit.
To avoid the dangers of fire, electric hazards and equipment damage, be sure to use only
the specified voltage when operating the FP.
Since there is no power switch on the FP unit, be sure to attach a breaker-type switch to its
power cord.
Power Cord Diameter
0.75 mm
2
to 2.5 mm
2
(18 AWG to 12 AWG)
Conductor Type
Simple or Twisted Wire
Conductor Length
• If the Conductor’s end (individual) wires are not twisted correctly, the end wires
may either short against each other, or against an electrode.
10 mm [0.39 in.]