B-29

OPERATION

B-29

The bent sample can also be rotated for further visual
inspection by using the joystick. FaceBend visual
inspection Passed.

FaceBend Visual Passed

BEND TEST FAILURE:

The VRTEX

®

360 will visually inspect the weld before

allowing it to be bent. If the weld passes the visual
inspection, the user can move proceed with the bend
test. If a weld fails the bend test, the details such as a
percentage of failure will be displayed in the informa-
tion box on the right side of the screen. The weld fail-
ure is measured in three different aspects including
Lack of Fusion, Porosity, and Slag Inclusion. If the
user fails the bend test there will not be a virtual bend
test certificate in the student report.

Beginning to Fail

Failed

Percentages of RootBend Failure

Joystick Rotate RootBend Failure

VRTEX

®

360