beautypg.com

Troubleshooting, Caution, On board ledʼs for the stt switch pc board – Lincoln Electric IM10057 POWER WAVE STT MODULE (CE) User Manual

Page 25: Stt switch pc board

background image

E-5

TROUBLESHOOTING

E-5

POWER WAVE

®

STT

®

MODULE (CE)

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

MACHINE

OUTPUT

ON/OFF

ON

ON

ON/OFF

LED1

(GATE)

ON

OFF

OFF

OFF

LED2

(STATUS)

ON

ON

OFF

OFF

LED3

(+15V)

ON

ON

ON

ON/OFF

STT SWITCH PC BOARD

ON BOARD LEDʼS FOR THE STT SWITCH PC BOARD

INDICATION

Normal Condition – STT

®

Switch is ON.

Normal Condition – STT

®

Switch has been commanded OFF.

Note: During normal STT

®

operation the OFF state of the LED

may only be detectable as a slight dimming.

Status Failure (only when triggered). Should be accompanied by
Error 99 on the external STT Module Status LED. Most likely
caused by weld cable misconnection (reverse polarity).

Status Failure (constantly). Should be accompanied by Error 99
on the external STT Module Status LED. Most likely caused by the
on board power supply under-voltage lockout. Verify input voltage
to the STT Switch board.

G6768-1

STT SWITCH

C1

C2

LED2

LED3

LED1

B1

B2

B3

B4

B5

B6

B7

B8

B9

J3

J2

J1

DIFFERENTIAL I/O

(STT SWITCH SIGNAL)

STT STATUS

(OUTPUT)

INPUT POWER

(40 VDC)

STT IN

(B1 - B4)

STT OUT

(B5 - B8)

SNUBBER