beautypg.com

Maintenance, Safety precautions, Routine maintenance – Lincoln Electric IM10057 POWER WAVE STT MODULE (CE) User Manual

Page 20: Calibration specification, Warning

background image

D-1

MAINTENANCE

D-1

POWER WAVE

®

STT

®

MODULE (CE)

SAFETY PRECAUTIONS

ELECTRIC SHOCK can kill.
• Disconnect input power before

servicing.

• Do not operate with covers removed.
• Do not touch electrically live parts.
• Only qualified persons should install,

use or service this equipment.

------------------------------------------------------------------------

See additional warning information

throughout this operator’s manual and
the Engine manual as well.

-----------------------------------------------------------

ROUTINE MAINTENANCE

Routine maintenance consists of periodically blowing

out the machine, using a low-pressure air stream, to
remove accumulated dust and dirt from the intake and
outlet louvers, and the cooling channels in the
machine. Also verify the STT

®

Module fan is opera-

tional when the power source fan is activated.

CALIBRATION SPECIFICATION

Due to the nature of its operation, calibration of the
STT

®

Module is not required. From a system perspec-

tive, the output calibration of the power source and
wire feeder should be performed as directed in their
respective instruction manuals.

When calibrating the power source voltage using the

Weld Manager utility, the actual output voltage should
be monitored directly at the output of the power
source (not the STT

®

Module output). This is

necessary because the default calibration mode
senses voltage directly from the power source output
studs. The STT

®

Module has no effect on the output

current calibration.

WARNING