E-3

TROUBLESHOOTING

E-3

ARC TRACKER™

USING THE STATUS LED TO TROUBLESHOOT SYSTEM PROBLEMS

Not all of the Arc Tracker™ errors will be displayed on the user interface. If a problem occurs it is important to note the con-
dition of the status lights. Therefore, prior to cycling power to the system, check the power source status light for error
sequences as noted below.

Error conditions are indicated in the following Table E.1.

Light

Condition

Steady Green

Blinking Green

Alternating Green and Red

Meaning

System OK.

Occurs during power up or a system reset. Normal for first 1-10 sec-

onds after power is turned on, or if the system configuration is changed

during operation.

Non-recoverable system fault. If the Status lights are flashing any com-

bination of red and green, errors are present. Read the error code(s)

before the machine is turned off.

Error Code interpretation through the Status light. Individual code

digits are flashed in red with a long pause between digits. If more than

one code is present, the codes will be separated by a green light. Only

active error conditions will be accessible through the Status Light.

Error codes can also be retrieved with the Diagnostics Utility (includ-

ed on the Service Navigator CD or available at www.power-

wavesoftware.com). This is the preferred method, since it can access

historical information contained in the error logs.

To clear the active error(s), turn power source off, and back on to

reset.

TABLE E.1

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION