SETUP MENU FEATURES
The Setup Menu gives access to the Setup
Configuration. Stored in the setup configuration are
user parameters that generally only need to be set at
installation. The parameters are grouped as shown in
the following table.
SET-UP FEATURES MENU
(See Figure B.1)
1. To access the set-up menu, press the Right and
Left buttons of the Main Display panel simultane-
ously. Note that the set-up menu cannot be
accessed if there is a fault (The status LED is not
solid green).
Change the value of the blinking parameter by rotat-
ing the Center knob.
2. After changing a parameter it is necessary to press
the Right hand button to save the new setting.
Pressing the Left button will cancel the change.
3. To exit the set-up menu at any time, press the
Right and Left buttons of the Main Display panel
simultaneously. Alternately, 1 minute of inactivity
will also exit the set-up menu.
PARAMETER
DEFINITION
P.1 through P.99
Unsecured Parameters
(always adjustable)
P.101 through P.199
Diagnostic Parameters
(always read only)
P.501 through P.599
Secured Parameters
(only accessible through a p.c.
application)
B-6
OPERATION
B-6
ARC TRACKER™
USER DEFINED PARAMETERS
Parameter
Definition
Exit Setup Menu
P.0
This option is used to exit the setup menu. When P.0 is displayed, press the Left Button to exit
the setup menu.
P.83
Calibration
See Calibration Specification section for further details.
P.106
View Ethernet IP Address
Used for viewing the IP address of Ethernet compatible equipment. Press the Right Button to
read the IP Address. Press the Left Button to back out and exit this option. The IP address
cannot be changed using this option.
P.505
Setup Menu Lock
Determines if the setup parameters can be modified by the operator without entering a pass-
code.
No = The operator can change any set menu parameter without first entering the passcode
even if the passcode is non-zero (default).
Yes = The operator must enter the passcode (if the passcode is non-zero) in order to change
any setup menu parameters.
This parameter can only be accessed using Power Wave Manager software.
P.506
Set User Interface Passcode
Prevents unauthorized changes to the equipment. The default passcode is zero which allows
full access. A nonzero passcode will prevent unauthorized changes to setup parameters (if
P.505 = Yes).
This parameter can only be accessed using Power Wave Manager software.
P.509
UI Master Lockout
Locks all user interface controls, preventing the operator from making any changes. This para-
meter can only be accessed using Power Wave Manager software.