Installation, Technical specifications – Lincoln Electric IM10090 ARC TRACKER User Manual
Page 10
ARC TRACKER™
A-1
INSTALLATION
A-1
TECHNICAL SPECIFICATIONS -
ARC TRACKER™
RATED OPERATING RANGE NEMA EW1
INPUT VOLTAGE AND CURRENT
Model
K3019-1
Volts at Rated Amperes
44 V DC
Amperes
1000 A DC
Duty Cycle
100%
Input Amperes
0.8-0.5 A
Input Voltage ± 10%
120-230 V AC, 50/60 Hz
* All attachment plugs must comply with the Standard for Attachment Plugs and Receptacles, UL498.
RATED OPERATING RANGE IEC60974-1
Volts at Rated Amperes
44 V DC
Amperes
1000 A DC
Duty Cycle
100%
VOLTAGE
50/60 Hz
120
230
230
Input
Amperes
0.8 A
0.5 A
0.5 A
PLUG
NEMA 5-15P (INCLUDED)
ANY NEMA 250 V TYPE*
CEE 7/ 7
INPUT CORD
3 CONDUCTOR, #18 AWG
TYPE S, SO, SOO, ST, STO, STOO OR
EQUIVALENT EXTRA HARD USAGE CORD
3 CONDUCTOR, 1.0 mm
2
HAR
REGION
NORTH
AMERICA
EUROPE
RECOMMENDED INPUT WIRE
PHYSICAL DIMENSIONS
TEMPERATURE RANGES
HEIGHT
12 in (305 mm)
MODEL
K3019-1
WIDTH
9 in (220 mm)
DEPTH
15 in (380 mm)
WEIGHT
20 lbs ( 9 kg)
OPERATING TEMPERATURE RANGE
STORAGE TEMPERATURE RANGE
14°F TO 104°F (-10°C TO 40°C)
-40°F TO 185°F (-40°C TO 85°C)
VOLTMETER
AMMETER
ENERGY
± 2% + 0.1**
± 2% + 2**
± 5%
METER ACCURACY (AS SHIPPED)
**Accuracy is expressed as +/- [Percentage of Reading + Digits].
For example: 10A = +/- 10A x 0.02 + 2 = 10A +/- 2.2, or 7.8A to 12.2A