P.83, Maintenance – Lincoln Electric IM10090 ARC TRACKER User Manual

Page 22

background image

D-3

MAINTENANCE

D-3

1. With the power source off, connect the ARC

TRACKER™ being calibrated to input power and
turn the ARC TRACKER™ on.

2. Enter into the calibration menu by pressing both

the left and right push buttons on the ARC TRACK-
ER™ user-interface. The Calibration Mode LED
will illuminate and the message display will look
like this:

3. Turn the center knob until parameter P.83 is

reached. Press the right pushbutton to enter into
Calibration mode.

4. With the power source turned off, press the right

pushbutton to zero the unit. The unit will take a few
seconds to zero.

5. Turn on the power source to provide the maximum

calibration current and voltage, e.g. 1000 A, 44 V.
The ARC TRACKER™ will begin to display the volt-
age, amperage, & arc time, and will begin to calcu-
late and display heat input.

6. Press the right push button to begin calibration of

the volt meter and ammeter located on the ARC
TRACKER™ under calibration.

ARC TRACKER™

Adjustment Procedure:

ARC TRACKER™ Front Panel

FIGURE D.2

AMMETER
DISPLAY

VOLT METER
DISPLAY

AMMETER
CALIBRATION
ADJUST

VOLT METER
CALIBRATION
ADJUST

CALIBRATION
MODE LED

MESSAGE
DISPLAY

LEFT PUSH
BUTTON

RIGHT
PUSH
BUTTON

CENTER
KNOB

P.0

User

Exit

Prefs

P.83

Calibrate V & I ?

Yes

P.83

Please Wait...

P.83

Adjust Knobs

Done

P.83

Is output OFF?

Yes

Cancel

P.83

Enable Output

Cancel