Bios menu 15: fan 1 configuration – IEI Integration IMB-C2160 User Manual
Page 109
IMB-C2160 Mic ro -ATX Mo th e rb o a rd
P a g e 94
Aptio Setup Utility – Copyright (C) 2011 American Megatrends, Inc.
Advanced
Smart Fan Mode Configuration
FAN 1 Smart Fan Control
[Auto Duty-Cycle Mode]
Temperature 1
60
Temperature 2
50
Temperature 3
40
Temperature 4
30
Duty Cycle 1
85
Duty Cycle 2
70
Duty Cycle 3
60
Duty Cycle 4
50
FAN 2 Smart Fan Control
[Auto Duty-Cycle Mode]
Temperature 1
60
Temperature 2
50
Temperature 3
40
Temperature 4
30
Duty Cycle 1
85
Duty Cycle 2
70
Duty Cycle 3
60
Duty Cycle 4
50
FAN 3 Smart Fan Control
[Auto Duty-Cycle Mode]
Temperature 1
60
Temperature 2
50
Temperature 3
40
Temperature 4
30
Duty Cycle 1
85
Duty Cycle 2
70
Duty Cycle 3
60
Duty Cycle 4
50
Smart Fan Mode Select
---------------------
: Select Screen
↑ ↓: Select Item
Enter
Select
+ - Change Opt.
F1
General Help
F2
Previous Values
F3
Optimized Defaults
F4
Save & Exit
ESC Exit
Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc.
BIOS Menu 15: FAN 1 Configuration
FAN 1 Sm a rt Fan Co n tro l [Au to Du ty-Cyc le Mo d e]
Use the FAN 1 Smart Fan Control option to configure the FAN 1 Smart Fan.
Manual
RPM
Mode
The fan spins at the speed set in Manual by
RPM settings
Manual Duty
Mode
The fan spins at the speed set in Manual by Duty
Cycle settings
Auto RPM Mode
The fan adjusts its speed using Auto by RPM
settings