Diagram C

–8

°

4" to 40"

+8

°

–10

°

8" to 80"

+10

°

Allowable Angle of Tilt

10V

20mA

0V

4mA

40"
80"

4"
8"

40" Range
80" Range

Adjustable

Maximum Analog Ranging

Target

Maximum Analog Ranging

Analog sensing in the maximum range means
uti liz ing the entire 36" span (4"-40") and 72" span
(8"-80"). To adjust, set your target at the min i mum
range, either 4" or 8" and adjust P1 to 4mA. Move
the target to the maximum range and adjust P2 to
20mA. Re-check read ings and make ap pro pri ate
ad just ments, if necessary. See di a gram (B).

Inverted Analog Outputs

Inverted outputs means that the 4-20mA or 0-10V
output signal will decrease proportionally with
dis tance. To adjust, place your target at the
min i mum sensing distance and ad just P1 to 20mA.
Place your target at the max i mum sensing dis tance
and adjust P2 to 4mA. Re-check read ings and
make ap pro pri ate ad just ments, if nec es sary. See
diagram (C).

LED Operation

( Not e D)

The LED is green when the unit is powered up.
It will fade to red as a target is detected with
in creased intensity as more sig nal is be ing
re flect ed from the target. Note: Any color other
than green equals a workable signal level.

Adjustment Pots

Zero and Span Control

Op er a tion and Set-Up

Minimum analog ranging is when you desire to
have the full 4-20mA or 0-10V output over the
minimum 5 inch sensing span. 5 inches of
min i mum sensing span can be adjusted any where
in the sensing range. For example 10"-15" or
25"-30". To make this ad just ment, you place your
target at the minimum sensing range and adjust
P1 to 4mA. Then move your target to the
max i mum sensing range and adjust P2 to 20mA.
Re-check the readings and make appropriate
ad just ments, if necessary. See diagram (A).

Minimum Analog Ranging

P1

P2

LED

0V

4mA

10V

20mA

40"
80"

4"
8"

40" Range
80" Range

Adjustable

Inverted Analog Ranging

Target

10V

20mA

0V

4mA

15"
24"

10"
12"

40" Range
80" Range

Adjustable

Minimum Analog Ranging

Target

Beam Spread vs. Target Distance

1.5

Beam Diameter (in.)

2.0

3.5

4.5

5.0

6.5

8.0

8.5

9.0

9.0

4

0

Distance from Sensor (in.)

6

8

10

12

16

20

24

28

30

4.5

Beam Diameter (in.)

8.0

10.0

13.0

14.0

14.5

14.5

10

0

Distance from Sensor (in.)

20

30

40

50

60

72

Diagram A

Diagram B