Mechanical Data

Drag

Maximum

Inertia

Unit

Part

Torque

Torque

Speed

Input

Output

Weight

Number

(lb. in.)

(lb. in.)

(rpm)

(in. lb.

2

)

(in. lb.

2

)

(lbs.)

PMC-10A3

5401-270-111

8.6

.25

1800

.239

.0291

2.0

PMC-20A3

5401-270-121

17

.51

1800

.413

.0752

2.9

PMC-40A3

5401-270-131

34

1.0

1800

1.14

.372

5.5

4

Warner Electric • 800-825-9050

819-0369

Electrical Connections

To avoid injury (or even death),

always make certain all power is off before
attempting to install or service the control or
any electrical equipment.

The PMC-A3's operate on DC voltage. Warner
Electric offers a full line of AC powered controls
to meet the needs of almost every application.
The service and installation instructions included
with each Warner Electric control show the
proper electrical connections.

After wiring your Magnetic Particle unit, confirm
that the control circuit is functioning. Without
rotating the input shaft, verify that voltage is
applied when the control output is turned on.
Also, if appropriate, set the current for the prop-
er output. Your magnetic particle unit is now
ready for operation. For information on start up
and maintenance, see page 4 of this manual.

Electrical Data

Electrical Coil Data

Torque

Torque

Unit Size

Voltage

Resistance

Amperes

Watts

Build Up

Decay

[ohms @ 75°F (25°C)]

[@ 75°F (25°C)] [@ 75°F (25°C)]

(msec)

(msec)

10

24

35.1

0.684

16.4

20

8

20

24

31.6

0.760

18.2

30

10

40

24

26.3

0.912

21.9

40

12

Note: Build up time equals time for torque to build to approximately 63.2% of steady state value
after a step change in voltage. Decay time equals time for current to drop to approximately 36.8%
of the steady state value after a voltage change.

Start Up

The powder in the magnetic particle units some-
times settles during shipment and will need to
be redistributed. A simple run-in procedure
should be performed to ensure proper perform-
ance.

Run in Procedure
Notes: 1. Before running in, make sure the unit

does not bind. See step 2 of the pre-
mounting instructions.

2. If mounted as a clutch, the output

shaft must be locked to prevent it
from turning.

Set the control output voltage for 5 to 6 volts.
Turn off the control and run the input for one
minute. Run at a speed close to, but not
exceeding 1000 RPM. Then cycle the unit at 5
or 6 volts for five seconds and off for ten sec-
onds. Repeat this for 20 cycles.

When the powder is redistributed properly, the
torque will be consistent and proportional to
current.