10
F1.3 – Calibration
F1.3.1 GEO Adjustment
Selection:
0…31 (Factory default16)
F1.3.2 – Linearity
Selection:
On
- Enabled
OFF - Disabled (Factory default)
F1.3.3 – Calibration
z If F1.3.2 is set to On
[E SCL] Empty scale.
Remove any load from scale platform, then press Enter to confirm. Terminal will
count down from[10 CAL] to [ 0 CAL].
[FULL Ld] Add full load.
Add load on the scale platform, then press Enter.
[000000] Input weight number, then press Enter to confirm. Terminal will count
down from[10 CAL] to [ 0 CAL].
[ donE ] Complete.
z If F1.3.2 is set to OFF
[E SCL] Empty scale.
Remove any load from scale platform, then press Enter to confirm. Terminal will
count down from[10 CAL] to [ 0 CAL].
[Add Ld]Add middle load
Add load on the scale platform, then press Enter.
[000000] Input weight number, then press Enter to confirm. Terminal will count
down from[10 CAL] to [ 0 CAL].
[FULL Ld] Add full load.
Add load on the scale platform, then press Enter.
[000000] Input weight number, then press Enter to confirm. Terminal will count
down from[10 CAL] to [ 0 CAL].
[ donE ] Complete.
F1.4 – Zero Function
F1.4.1 – AZM
Selection:
OFF,0.5d(Factory default),1d,3d
F1.4.2 – Power up Zero
Selection:
OFF,2%,10%(Factory default),20%
F1.4.3 – Pushbutton Zero
Selection:
OFF,2%(Factory default),10%,20%
If F1.1 is set to OIML, Then F1.4.2 will set to 10%, and F1.4.3 will set to 2%.
F1.5 – Tare Function