Troubleshooting and Diagnostics

Status / Warning

Cause

Remedy

PdeC

PID Deceleration Status

PID setpoint has finished

its ramp but the drive is still

decelerating to a stop.

PID

PID Mode Active

Drive has been put into PID

Mode. See P200.

SLP

Sleep Mode is active

See P240...P242

SP

Start Pending

The drive has tripped into a

fault and will automatically

restart (P110 = 3...6)

To disable Auto-Restart, set

P110 = 0...2

spd

PID Mode disabled.

Drive has been taken out of PID

Mode. See P200.

stoP

Output frequency = 0 Hz

(outputs U, V, W inhibited)

Stop has been commanded

from the keypad, terminal strip,

or network

Apply Start command (Start

Control source depends on

P100)