36

Function

No.

Description

Code

Factory

Setting

6.00*

Software Version

6.01*

Drive Horsepower

6.02*

Fault Log 1

6.03*

Fault Log 2

6.04*

Fault Log 3

6.05**

Reset Drive to Factory Setting

1110: 50 Hz Operation

1111: 60 Hz Operation

0000

FUNCTION GROUP 6 – DRIVE STATUS AND RESET

* Read only.

** Functions which can only be changed while the drive is in the Stop Mode.

Function

No.

Description

Range/Code

Factory

Setting

7.00*

Multi-Function Input Terminal 1

(1)

0000: Preset Frequency Operation

(2)

0001: Preset Frequency Operation

(2)

0002: Preset Frequency Operation

(2)

0003: Up Frequency Command (See Function No. 7.14)

(3)

0004: Down Frequency Command

(See Function No. 7.14)

(3)

0005: Accel/Decel 2 (See Function No. 7.16)

0006: Forward/Stop Command

(4)

0007: Reverse/Stop Command

(4)

0008: External Fault (N.O. Contact)

0009: Reset

0010: N.O. Start (2-Wire or 3-Wire Start/Stop)

(4)

0011: N.C. Stop (3-Wire Start/Stop)

(4)

0012: External Fault (N.C. Contact)

0000

7.01*

Multi-Function Input Terminal 2

(1)

0001

7.02*

Multi-Function Input Terminal 3

(1)

0002

7.03*

Multi-Function Input Terminal 4

(1)

0009

7.04*

Multi-Function Input Terminal 5

(1)

0010

7.05*

Multi-Function Input Terminal 6

(1)

0003

7.06*

Multi-Function Input Terminal 7

(1)

0004

7.07

*

Preset Frequency 1 (Hz)

0.00 – 240.0

5.00

7.08

*

Preset Frequency 2 (Hz)

0.00 – 240.0

10.00

7.09

*

Preset Frequency 3 (Hz)

0.00 – 240.0

20.00

7.10

*

Preset Frequency 4 (Hz)

0.00 – 240.0

25.00

7.11

*

Preset Frequency 5 (Hz)

0.00 – 240.0

30.00

7.12

*

Preset Frequency 6 (Hz)

0.00 – 240.0

35.00

7.13

*

Preset Frequency 7 (Hz)

0.00 – 240.0

40.00

7.14

*

Up/Down Frequency Control Mode

0000: Free-Running

(5)

0001: Incremental Change (See Function No. 7.15)

0000

7.15

*

Increment of Up/Down Frequency (Hz)

0.01 – 30.00

1.00

7.16

*

Accel/Decel 2 Time (Seconds)

0.3 – 180.0

1.5

FUNCTION GROUP 7 – MULTI-FUNCTION INPUT TERMINALS
(IODA OPTION BOARD REQUIRED)

Note: (1) Each of the 7 Multi-Function Input Terminals can be programmed for any of the respective function codes (0000 – 0011).

(2) Preset Frequencies 1 – 7 are obtained by selecting a specific combination of 3 Multi-Function Input Terminals. The specific frequencies

are programmed in Functions 7.07 – 7.13. (3) For Up/Down Frequency Commands (codes “0003” and “0004”), Frequency Control

(Function No. 2.00) must be set to Up/Down Using MFITs (code “0005”). (4) For Forward/Reverse Stop Commands (codes “0006” and

“0007”) and N.O. Start / N.C. Stop (codes “0010” and “0011”), Run/Stop-Forward/Reverse Control (Function No. 1.00) must be set to

External Contacts (code “0001”). (5) The rate of change of the “UP” Control for frequency setting, using external contacts, is proportional to

the Accel Time setting (3.03). The rate of change of the “DOWN” Control for frequency setting, using external contacts, is proportional to the

Decel Time Setting (3.04).

*Functions which can only be changed while the drive is in the Stop Mode.