beautypg.com

Figure 23 – function no. description – KB Electronics KBDA-48 User Manual

Page 31

background image

31

9.5

FAULT RECOVERY – The drive monitors many faults. See Function No. 1.05, on page 33, for

restarting the drive after a fault has been cleared. See Section 9.4, on page 30, for the Digital

Readout Codes. See Section 11, on page 41, for descriptions of the Diagnostic LEDs. See

Appendix A, on page 42, for IODA faults.

Drive Faults – Undervoltage (“–LU–”), Overvoltage (“–OU–”), Short Circuit at the motor (phase-to-

phase) (“–SC–”), I2t or I•t Fault (“OL–t”), and Phase Loss Detection (Models KBDA-29*, 45, 48

only) (“–PL–”).

*When used on 3-phase AC line input set for 7.0 Amps or higher (3 HP (2.25 kW)).

10 PROGRAMMABLE FUNCTION SUMMARY LIST

All functions have been factory set, as shown in the tables on pages 32 – 40. The Detailed

Programmable Function List (Part No. A42035) is available – contact our Sales Department.

Programming Mode – When the drive is put into the Programming Mode (see Figure 23), a Function

No. will be displayed. A Function No. consists of a Group No. (digits on the left side of the decimal

point) and a Group No. Code (digits on the right side of the decimal point). The digits can be changed

using the Up and Down Keys. The Left Shift Key is used to move the changeable digit.

When the READ Key is pressed, either a Code or Value will be displayed. Codes have specific descrip-

tions. Values have numeric ranges.

Application Note – The programming of the drive can be performed without a motor connected. On

drives with 3-phase AC line input requirements, the programming can be performed with single-phase

AC line input. The drive’s Phase Loss Detection will not trip the drive without the motor connected.

To program multiple drives, the optional DownLoad Module™ (Part No. 9582) can be used to upload

the drive program and facilitate downloading it to multiple drives.

FIGURE 23 – FUNCTION NO. DESCRIPTION

Press Program Key

Function No.

to Display

and

(Digital Display Modes)

Group No. Digit Flashes

to Read Code

Press Read Key

Code Displayed

Value Displayed

Press Program Key

to Display

Function No.

Press Read Key

to Read Value

Group No. Digit Flashes

(Drive Operating Parameters)

and

Function No. which Contains a Code

Function No. which Contains a Value

(Frequency)

(1.5 Seconds)

Group No. Code Digits are Shown

(Display Mode)

Group No. Code Digits are Shown

(Accel Time)

This manual is related to the following products: