beautypg.com

Figure 15 – typical hi-pot test setup – KB Electronics KBDA-48 User Manual

Page 21

background image

9

DRIVE OPERATION

Before operating the drive, read Section 9.2, for instructions on the Digital Keypad Operation. See

Figure 2, on page 10, for the keypad layout.

The 4-digit display can indicate various functions of the drive: Set Frequency, Motor RPM, Output

Current and Voltage, Custom Units, Function Numbers, Function Codes or Values, and Fault Codes.

See Section 9.4, on page 30.

See Section 9.3, on pages 22 – 29, for information on programming the drive. If an error message

appears while programming the drive, see Section 9.5, on page 31.

9.1

START-UP PROCEDURE – After the drive has been properly setup and all connections complet-

ed, the start-up procedure can begin. If the AC power has been properly brought to the drive, the

LEDs will indicate the drive’s status, as described in Section 11, on page 41. See Section 9.4, on

page 30, for the Digital Readout Codes.

To start the drive, press the RUN Key. The motor will begin to accelerate to the Set Frequency.

The factory set frequency is 05.00 Hz.

9.2

KEYPAD DESCRIPTION – The Keypad has eight (8) keys, which are used to program drive func-

tions, as described in Table 6, on page 22. The eight (8) LEDs provide indication of the drive’s

21

8.2

The hi-pot tester must have an automatic ramp-up to the test voltage and an automatic ramp-

down to zero voltage.

Note: If the hi-pot tester does not have automatic ramping, then the hi-pot output must be manu-

ally increased to the test voltage and then manually reduced to zero. This procedure must be fol-

lowed for each machine to be tested. A suggested hi-pot tester is Slaughter Model 2550.

CAUTION! Instantly applying the hi-pot voltage will cause irreversible damage to the drive, which

will void the warranty.

FIGURE 15 – TYPICAL HI-POT TEST SETUP

Chassis

Chassis

Machine Equipment or Frame

Adjustable Frequency Drive

L2

(Main Power Disconnected)

to AC Line Inputs

Connect Hi-Pot

L2

L1

Auxiliary Equipment

L3

AC Line Input

H. V.

MAX

ZERO

L1

RESET

RETURN

10mA

0mA

VOLTAGE

TEST

AC KILOVOLTS

LEAKAGE

1

0

3

2

High Voltage Dielectric Withstand Tester (Hi-Pot Tester)

V

Motor Wires

W

Frame

Connect All Drive Terminals Together

(Main Power Disconnected)

U