13.1 Minimum Speed (MIN) – Sets the minimum speed of the

motor. The MIN Trimpot is factory set to 0% of frequency set-

ting. For a higher minimum speed setting, rotate the MIN

Trimpot clockwise. See Figure 22.

13.2 Maximum Speed (MAX) – Sets the maximum speed of the

motor. The MAX Trimpot is factory set to 100% of frequency

setting. For a higher maximum speed setting, rotate the MAX

Trimpot clockwise. For a lower maximum speed setting, rotate

the MAX Trimpot counterclockwise. See Figure 23.

13.3 Acceleration (ACC) – Sets the amount of time for the motor

to accelerate from zero speed to full speed. The ACC Trimpot

is factory set to 1.5 seconds. For longer acceleration time,

rotate the ACC Trimpot clockwise. For more rapid acceleration,

rotate the ACC Trimpot counterclockwise. See Figure 24.

Note: Rapid acceleration settings may cause the current limit

circuit to activate, which will extend the acceleration time.

13.4 Deceleration (DEC/B) – Sets the amount of time for the motor

to decelerate from full speed to zero speed. The DEC/B

Trimpot is factory set to 1.5 seconds. For longer deceleration

time, rotate the DEC/B Trimpot clockwise. For more rapid

deceleration, rotate the DEC/B Trimpot counterclockwise. See

Figure 25, on page 40.

39

% Frequency Setting

(Shown Factory Set to 0%)

0

15

40

35

30

FIGURE 22 – MINIMUM SPEED

TRIMPOT (MIN) RANGE

(Shown Factory Set to 100%)

% Frequency Setting

70

75

100

110

90

80

FIGURE 23 – MAXIMUM SPEED

TRIMPOT (MAX) RANGE

10

(Shown Factory Set to 1.5 Seconds)

Seconds

1.5

.3

3

20

17

FIGURE 24 – ACCELERATION

TRIMPOT (ACC) RANGE