beautypg.com

KB Electronics KBVF-23P User Manual

Page 24

background image

6.1

AC Line Input Voltage Selection

(Jumper J1 (Models KBVF-21D,

22D, 23D, 24D, 26D Only)) –

Jumper J1 is factory set to the

“230V” position for 208/230 Volt

AC line input. For 115 Volt AC line

input, set Jumper J1 to the

“115V” position. Jumper J1 is

located on the upper PC board.

See Figures 7 and 8.

For 115 Volt AC line input, on

Model KBVF-26D, the jumper

must be removed and

installed onto the

“115VAC” position. Using

pliers, gently rock the

female terminal back and

forth vertically while

pulling it upward. See

Figure 9, on page 25.

24

FIGURE 7 – MODELS KBVF-21D, 22D, 23D, 24D

AC LINE INPUT VOLTAGE SELECTION

230 Volt AC Line Input

(Factory Setting)

(J1 Installed in “230V” Position)

115 Volt AC Line Input

(J1 Installed in “115V” Position)

J1

230V 115V

230V 115V

J1

FIGURE 8 – MODEL KBVF-26D AC LINE INPUT VOLTAGE SELECTION

230 Volt AC Line Input

(Factory Setting)

(J1 Installed in “230VAC” Position)

115 Volt AC Line Input

(J1 Installed in “115VAC” Position)

install it onto the "115VAC" position.

For 115 Volt AC Line Input,

remove this terminal and

this terminal.

Do not remove

115VAC

J1

230VAC

115VAC

230VAC

J1