beautypg.com

Figure 15 – typical hi-pot setup – KB Electronics KBVF-23P User Manual

Page 29

background image

29

P2

P3

P1

Chassis

Adjustable Frequency Drive

Signal Inputs

L2

L1

W

V

U

High Voltage Dielectric Withstand Tester (Hi-Pot Tester)

10mA

0mA

LEAKAGE

AC KILOVOLTS

RESET

TEST

ZERO

MAX

VOLTAGE

0

2

1

3

to Both AC Line Inputs

(Main Power Disconnected)

Connect Hi-Pot

AC Line Input

H. V.

RETURN

Machine Equipment or Frame

L2

L1

Auxiliary Equipment

Chassis

Connect All Drive Terminals Together

Motor Wires

Frame

(Main Power Disconnected)

FIGURE 15 – TYPICAL HI-POT SETUP

9

WIRING INSTRUCTIONS

WARNING! Read Safety Warning, on pages 8 and 9, before using the drive.

Disconnect main power before making connections to the drive. To avoid electric

shock, be sure to properly ground the drive.