KB Electronics KBVF-23P User Manual
Page 34
34
FIGURE 21 – ENABLE SWITCH CONNECTION
Jumper Removed
Connector Installed for
Forward Enable Switch
Connector Installed for
Reverse Enable Switch
CON2
F - S - R
(Close to Run)
Red *
(Open to Stop)
Black
White
Enable Switch
CON2
Forward
(Close to Run)
Red
(Open to Stop)
Black
White*
Enable Switch
CON2
Reverse
*For Forward Enable Switch connection, the red wire is not used. For Reverse Enable Switch connection, the white wire is
not used. The unused wire must be insulated or it may be cut off at the connector.
9.7
Forward-Stop-Reverse
Switch Connection (CON2) –
To operate the drive using a
Forward-Stop-Reverse Switch,
remove the factory installed
jumper on CON2 and install
the 3-wire connector (sup-
plied). CON2 is located on the
lower PC board. The connec-
tor must be wired to a “main-
tained” switch or contact. See
Figure 20. Also see Forward/Reverse Speed Selection, in Section 6.4, on page 27.
Note: The drive can be factory programmed for momentary contact operation.
FIGURE 20 – FORWARD-STOP-REVERSE SWITCH CONNECTION
Jumper Removed
Connector Installed for
Forward-Stop-Reverse Switch
CON2
F - S - R
Forward-Stop-Reverse
Black
White
CON2
Red
Stop
Forward
Reverse
Switch