Local programming, Setting output, Function – IDEC DS2_Series User Manual
Page 14: Instruction manual ds2 series, Run time, Start-up

Instruction manual
DS2 series
13
6.1. Local programming
The function programming and selection is made
using dip-switches located inside the receiver unit
lid.
The following table indicates the type of function and
relative position of the dip-switches.
Setting Output
Dip
N.
Function
Active Pos
Mode Analogue Switching
Serial
ON
Local
- -
-
1A
Programming
mode
Run
Time
OFF
Remote
See remote setting
ON
Complete -
-
Complete
Beam Status
Array
2A
Serial output
analysis mode
Start-up
OFF
Partial -
-
Partial
ASCII
ON
Reference = First
Beam
(closest to connector)
V=V
Res
*N
BEAM
[Top; ref]
Incr. Ramp(0-10V)
-
Partial
Top Beam
3A
Measurement
reference beam
Start-up
OFF
Reference = Last
Beam
V=10-V
Res
*N
BEAM
[Top; ref]
Decr. Ramp(10-0V)
Partial
Bottom Beam
ON
Top or Bottom
(Absolute Measure)
- -
-
4A
Measurement
analysis beam
Start-up
OFF
Total
(Relative Measure)
V=V
Res
*N
BEAM
[dark]
Partial
Total Beam
ON
Inactive Teach-in
(Normal mode)
- Presence
detection
-
1B
Teach-in
detection
analysis mode
Start-up
OFF
Active Teach-in
-
Conditional
presence detection
from Teach-in
-
ON
Absolute pos.
detection
-
Positional detection
of Teach-in ref.
object
-
2B
Teach-in
Mode
Start-up
OFF
Relative pos.
detection
-
Detection of Teach-
in reference object
-
ON
Normally
Open
-
Voltage on
switching device
during detection
-
3B
Switching
Output
Mode
Start-up
OFF
Normally
Closed
-
No voltage on
switching device
during detection
-
ON
No
Delay
- -
-
4B
Switching
Output
Delay
Start-up
OFF
100ms -
Restore from
detection
delay = 100ms
-
( - ) Shows that the state of considered dip-switch does not influence kind of output correlated; ouptut is old setting by state of
function of the others dip-switches.
The functions, with the exception of the programming mode, cannot be activated during device
functioning. The functions are activated at device powering.
1A 2A 3A 4A
ON
1B 2B 3B 4B
ON