IAI America RCB-ISL-SIO User Manual
Page 2
+24V
0V
Personal Computer
SIO Isolator
Terminal Resistance
SIO connector
24V
Power-
supply
Required Cables
USB Cable CB-SEL-USB
USB Conversion Adaptor RCB-CV-USB
(attachment to the PC application software RCB-CV-USB)
Isolator Communication Cable CB-RCB-SIO
□□□
External Machine Communication Cable CB-RCA-SIO
□□□
+24V
0V
+24V
+24V
0V
0V
+24V
0V
Master Unit
Gateway unit
Made by the client
SIO Isolator
SIO Isolator
Isolator Link Cable
External machine
communication
cable
Terminal Resistor
24V Power-
supply
PS1
24V Power-
supply
PS2
24V Power-
supply
PS4
24V Power-
supply
PS3
Controller
Controller
e-Con
Connector
Single-phase
(In case of SCON)
(3)
Connection Example 3:
In the case of the link connection through the gateway unit:
In the case that the 0V line for the power to each controller can not be shared, or the
DC24V type controllers are used together with the AC100/200V controllers, the power
source can be separated for each controller as shown in the figure.
Because the power to the primary circuit inside the SIO isolator is supplied from CN1, make
sure to connect CN1.
(4)
Connection Example 4: In the case that the PC is connected while the positive side of the
24V power is grounded:
Inside the most PCs, the GND (0V) line for the communication is short-circuited to FG
(frame ground), when the PC is connected, a short-circuit occurs in the 24V power line
which might cause the PC breakdown. In such case, connect the controller (including the
gateway and ROBONET) using the SIO isolator and USB conversion adaptor
(RCB-CV-USB) as shown in the figure.
1. The RS232C conversion unit RCB-CV-MW (attachment to the PC application software
RCM-101-MW) can not be used for the connection between the PC and SIO isolator.
2. Connect the external machine communication cable (3) to CN1 for the SIO isolator.
CAUTION
CAUTION