beautypg.com

D. residential garage installation, E. exhaust vent and intake pipe – HTP EL-399 User Manual

Page 14

background image

14

LP- 293 REV. 5.20.14

Figure 4

D. RESIDENTIAL GARAGE INSTALLATION

PRECAUTIONS
If the boiler is located in a residential garage, per ANSI Z223.1:

Mount the bottom of the boiler

a minimum of 18” above the floor of the garage, to ensure the burner and ignition devices are

well off the floor.

Locate or protect the boiler so it cannot be damaged by a moving vehicle.

E. EXHAUST VENT AND INTAKE PIPE

Vents must be properly supported. The boiler exhaust and intake connections are not designed to carry heavy weight. Vent support
brackets must be within 1’ of the boiler and the balance at 4’ intervals. Venting must be readily accessible for visual inspection for the
first 3’ from the boiler.

The boiler is rated ANSI Z21.13 Category IV (pressurized vent, likely to form condensate in the vent), and requires a special vent
system designed for pressurized venting.

This manual is related to the following products: