Warning, Caution – Harrington Hoists and Cranes MCR Trolley User Manual
Page 25

25
3.11.6
NOTICE
Where conditions dictate, the installation sequence can be reversed by connecting
the air supply first, followed by mounting the trolley hoist.
Figure 3-13
Typical Air Supply Connection
3.12 Pre-operational Checks and Trial Operation
3.12.1 Refer to the trolley's Nameplate and record the Code and Serial Number in the space provided on the
cover of this manual.
3.12.2 Refer to the hoist's owner's manual and perform all pre-operational checks for the hoist.
3.12.3 Perform pre-operational checks for the trolley:
WARNING
Confirm the adequacy of the rated capacity for all slings, chains, wire ropes
and all other lifting attachments before use. Inspect all load suspension members for damage prior
to use and replace or repair all damaged parts.
Ensure that trolley is properly installed on the beam, and stops for the trolley are correctly
positioned and securely installed on the beam.
Ensure that all nuts, bolts and split pins (cotter pins) are sufficiently fastened.
Pull down on the Pendant and ensure that the Strain Relief Cable takes the force, not the Pendant
Assembly.
CAUTION
Check air supply before everyday use. If the air supply volume and pressure
is not sufficient the hoist and trolley may not function normally.
3.12.4 Confirm proper operation.
Before operating read and become familiar with
Section 4
- Operation.
Before operating ensure that the hoist (and trolley) meets the Inspection, Testing and Maintenance
requirements of ANSI/ASME B30.16.
Before operating ensure that nothing will interfere with the full range of the hoist’s (and trolley’s)
operation.