Ummary of, Erial, Ommands – Gilderfluke&Co 16 Bit CD-Quality Digital Audio Systems User Manual
Page 81

- S
UMMARY OF
S
ERIAL
C
OMMANDS
-
Enter Setup Echo Mode:
"a" (CARD#)
Exit Setup Echo Mode:
"b"
Enter Global Echo Mode:
"c" (CARD#)
Exit Global Echo Mode:
"d"
Enter Echo All Mode:
"e" (CARD#)
Exit Echo All Mode:
"f"
Enter Echo Specific Mode:
"g"
Exit Echo Specific Mode:
"h"
Address Status Report:
"i" (CARD#)
Switch Status:
"l" (CARD#)
Enter Configuration Mode:
"m" (5AA5) (CARD#)
1/4 J6 Input Status:
"q" (CARD#)
Configuration Dump:
"r" (CARD#)
Load Configuration:
"s" (CARD#) (STRING)
Start Commands:
Start Card #:
"t" (CARD#) (1=left, 2=right, 3=both)
Start All:
"u" (1=left, 2=right, 3=both)
Start Cocked:
"v" (1=left, 2=right, 3=both)
Start Group:
"w" (GROUP#) (1=left, 2=right, 3=both)
Stop Commands:
Stop Card #:
"x" (CARD#) (1=left, 2=right, 3=both)
Stop All:
"y" (1=left, 2=right, 3=both)
Stop Cocked:
"z" (1=left, 2=right, 3=both)
Stop Group:
"G" (GROUP#) (1=left, 2=right, 3=both)
Reset Commands:
Reset Card #:
"H" (CARD#) (1=left, 2=right, 3=both)
Reset All:
"I" (1=left, 2=right, 3=both)
Reset Cocked:
"JÓ (1=left, 2=right, 3=both)
Reset Group:
"K" (GROUP#) (1=left, 2=right, 3=both)
Mute Commands:
Mute Card #:
"L" (CARD#) (1=left, 2=right, 3=both)
Mute All:
"M" (1=left, 2=right, 3=both)
Mute Cocked:
"N" (1=left, 2=right, 3=both)
Mute Group:
"O" (GROUP#) (1=left, 2=right, 3=both)
Half-Mute Commands:
Half-Mute Card #:
"P" (CARD#) (1=left, 2=right, 3=both)
Half-Mute All:
"Q" (1=left, 2=right, 3=both)
Half-Mute Cocked:
"R" (1=left, 2=right, 3=both)
Half-Mute Group:
"S" (GROUP#) (1=left, 2=right, 3=both)
G
ILDERFLUKE
& C
O
. ¥ 205 S
OUTH
F
LOWER
S
T
. ¥ B
URBANK
, C
ALIF
. 91502-2102 ¥ 818/840-9484 ¥
FAX
818/840-9485