Connections, jumpers and leds on the ser-dmx, 3 of 22 – Gilderfluke&Co DMX-512 Input Servo Motor Controller User Manual
Page 7
Connections, Jumpers and LEDs on the SER-DMX:
A) RS-422 Serial Port: This is used to configure the SER-DMX. Although
this connector uses an eight position connector instead of the usual
six, it is still compatible with all of the RS-422 Serial Ports used on
Gilderfluke & Company products. IF you are not using this connec-
tion to bring the DMX-512 into the SER-DMX, then you should use a
six conductor RJ-12 connector when attaching to the serial port.
If you have more than one SER-DMX plugged together side-by-
side, then only one of the cards should have the RS-422 serial data
from your computer attached to it.
The serial data signals from the SER-DMX are brought out on a
eight position RJ-45 (modular telephone style connector). Facing the
end of the cable with the release latch upwards, its pin out is as fol-
lows:
G
ILDERFLUKE
& C
O
.• 205 S
OUTH
F
LOWER
S
TREET
• B
URBANK
, C
ALIFORNIA
91502 • 818/840-9484 • 800/776-5972 •
FAX
818/840-9485
E
AST
C
OAST
/F
LORIDA
O
FFICE
• 7041 G
RAND
N
ATIONAL
D
RIVE
• S
UITE
128d • O
RLANDO
, F
L
. 32819 • 407/354-5954 •
FAX
407/354-5955
3 of 22