beautypg.com

Connections, jumpers and leds on the ser-dmx, 3 of 22 – Gilderfluke&Co DMX-512 Input Servo Motor Controller User Manual

Page 7

background image

Connections, Jumpers and LEDs on the SER-DMX:

A) RS-422 Serial Port: This is used to configure the SER-DMX. Although

this connector uses an eight position connector instead of the usual
six, it is still compatible with all of the RS-422 Serial Ports used on
Gilderfluke & Company products. IF you are not using this connec-
tion to bring the DMX-512 into the SER-DMX, then you should use a
six conductor RJ-12 connector when attaching to the serial port.

If you have more than one SER-DMX plugged together side-by-

side, then only one of the cards should have the RS-422 serial data
from your computer attached to it.

The serial data signals from the SER-DMX are brought out on a

eight position RJ-45 (modular telephone style connector). Facing the
end of the cable with the release latch upwards, its pin out is as fol-
lows:

G

ILDERFLUKE

& C

O

.205 S

OUTH

F

LOWER

S

TREET

B

URBANK

, C

ALIFORNIA

91502 818/840-9484 800/776-5972

FAX

818/840-9485

E

AST

C

OAST

/F

LORIDA

O

FFICE

7041 G

RAND

N

ATIONAL

D

RIVE

S

UITE

128d O

RLANDO

, F

L

. 32819 407/354-5954

FAX

407/354-5955

3 of 22