If you have selected twelve bits resolution for the outputs, then the

values will be displayed as follows. Note that addresses that can’t be used
for twelve bit vales are skipped in the ‘MSB address’ column. In this case the
value scale being used is percentage:

-Gilderfluke & Company - Sixteen Channel Servo Controller - ver1.04 - c1999 DCM-

a) card serial address at __0 MSB E minimum maximum forced PowerOn

b) first output addressed at __0 address I scale scale output default

c) DMX Rx checksum enabled- yes 1 (0) |Y|__49%__|__97%__|_______|___0%__|

2 (1) |Y|__49%__|__97%__|_______|___0%__|

g) numbering system- percent 4 (2) |Y|__49%__|__97%__|_______|___0%__|

h) VT-52 compatible display- yes 5 (3) |Y|__49%__|__97%__|_______|___0%__|

7 (4) |Y|__49%__|__97%__|_______|___0%__|

i) twelve bit resolution- yes 8 (5) |Y|__49%__|__97%__|_______|___0%__|

j) address to test & adjust- _14 10 (6) |Y|__49%__|__97%__|_______|___0%__|

k) test output- none 11 (7) |Y|__49%__|__97%__|_______|___0%__|

e) auto EaseIn- 2 seconds 13 (8) |Y|__49%__|__97%__|_______|___0%__|

p) set analog endpoints -> 14 (9) |Y|__49%__|__97%__|_______|___0%__|

q) force Output to a value 16 (A) |Y|__49%__|__97%__|_______|___0%__|

u) set min/max/forced using keypad 17 (B) |Y|__49%__|__97%__|_______|___0%__|

t) set PowerOn defaults 19 (C) |Y|__49%__|__97%__|_______|___0%__|

z) turn off servos on Zeros- all=0 20 (D) |Y|__49%__|__97%__|_______|___0%__|

22 (E) |Y|__49%__|__97%__|_______|___0%__|

r) download configuration 23 (F) |Y|__49%__|__97%__|_______|___0%__|

o) reload defaults

n) test & adjust next output l) test & adjust last output x) eXit

Enter Command-

All numeric values are entered in HEXadecimal (0-9, A through F)

or Decimal numbers (0-9), as selected on the menu. Each number consist
of one or more ASCII characters followed by a ( on
some keyboards). If more characters have been entered before the TURN> than are allowed, then the characters already entered will scroll to
the left to make room for the new entries. Once a command has been in-
voked, characters can be erased one-by-one by using the key
( on some keyboards). An entire entry can be erased by hit-
ting the ape key. A command can be canceled altogether by hit-
ting the key ( on some keyboards) or ape key
after all the characters have been erased or before any have been en-
tered.

Once you have configured a SER-DMX, you can ‘lock’ the configu-

ration by moving the ‘Write Protect’ jumper to the ‘Wp’ (Write Protect) posi-
tion from the ‘En’ (Enable) position. This should protect your configuration
from anything short of a lightning hit. The menu will change to show that

G

ILDERFLUKE

& C

O

.205 S

OUTH

F

LOWER

S

TREET

B

URBANK

, C

ALIFORNIA

91502 818/840-9484 800/776-5972

FAX

818/840-9485

E

AST

C

OAST

/F

LORIDA

O

FFICE

7041 G

RAND

N

ATIONAL

D

RIVE

S

UITE

128d O

RLANDO

, F

L

. 32819 407/354-5954

FAX

407/354-5955

13 of 22