Programming the flite 2 pump – SKC Limited Flite 2 User Manual
Page 17
www.skcltd.com
901-FTM Issue I
Page 15
Programming the Flite 2 Pump
To check the pump flow rate select the ‘YES’ menu option
and press
. The pump will run for 1 minute allowing the
flow rate to be checked with a flow calibrator. Alternatively,
select the ‘NO’ menu option and press
to display the
‘TIMER MODE’ screen.
CHECK FLOW ?
YES/no
Æ
FLOW CHECK IN PR
000:00:59 R00/01
When the flow rate has been checked press
to display
the next screen.
Æ
FLOW OK ?
YES/no
If the flow rate was correct select the ‘YES’ menu option and
press
to display the ‘TIMER MODE’ screen.
Æ
MODE = TIMED
OK ?
YES/no
If the flow rate was incorrect, select the ‘NO’ menu option and press
to set the correct flow rate as
detailed in section - Programming 2) Setting the Flow Rate. When the correct flow rate has been entered, the
‘CHECK FLOW ?’ menu screen is again displayed.
The remaining review data screens allow the timer settings to be checked and amended if required. When all
of the timer settings have been checked, the ‘REVIEW DATA ?’ menu screen is again displayed.
If all of the sample program settings are correct select the
‘NO’ menu option and press
, the ‘START NOW ?’
menu screen is displayed.
REVIEW DATA ?
yes/NO
Æ
START NOW ?
YES/no/escape