Introduction – SKC 100-3901 DPS (Deployable Particulate Sampler) System User Manual
Page 4
1
INTRODUCTION
The SKC DPS System is a compact, portable, batt ery-operated, and cost-eff ective
particulate sampling system that ensures the ability to monitor particulate matt er
(PM) in indoor and outdoor environments and in urban, industrial, or rural sett ings.
The system features the fully programmable constant fl ow Leland Legacy
®
Sample
Pump, the IMPACT Sampler, and other equipment needed for eff ective ambient
PM10 or PM2.5 sampling. All components are packaged in an easily carried heavy-
duty Pelican
®
case from which the system operates.
The heart of the DPS System is the patented* IMPACT Sampler. This inertial impactor
is designed to remove particles larger than a specifi c cut-point (2.5 μm or 10 μm) by
capturing them on a disposable oiled impaction disc that reduces particle bounce.
Particles smaller than the cut-point are collected on a 47-mm fi lter. The IMPACT
Sampler mounts easily and makes media changes fast and simple with its convenient
removable fi lter cassett e and opener.
* U.S. Patent No. 7,334,453
The SKC DPS System includes a Leland Legacy
Sample Pump with connection case
and charger (100-240 V), IMPACT sampling head, 2 fi lter cassett es, calibration adapter,
rain cover for sampling head, 25 disposable impaction discs, fi lter cassett e opener, tubing
with quick-connect fi tt ing, and mounting bracket in a heavy-duty lockable carry case.
Two external batt ery assemblies with adapters are packaged separately.
Calibration tubing
Mounting
bracket
Rain cover
Additional
fi lter
cassette
Leland Legacy
pump with
connection case
and cable
Tubing with
quick-connect fi tting
Quick-connect
release
Cassette
opener
Quick-connect fi tting
External battery
assemblies with
battery adapters (2)
World-wide plugs
for charger
Calibration adapter
Impaction discs
(25)
IMPACT sampler
with fi lter cassette
Charging unit and
power supply