Recommended Collection Filters for System (not supplied with system)
Select a fi lter based on your application; required for sampling
Quartz Filters, 47 mm, Tissuquartz

, 432 μm thick, pk/25

225-1823

PTFE Filters,

§‡

47 mm, 2.0-μm pore size, with PMP support ring, pk/50

225-1747

Sampling Heads/Replacement Parts
IMPACT Sampling Head
includes fi lter cassette, calibration adapter,
and rain cover for sampler; requires collection media (see above) and
impaction substrate (see below) sold separately

PM2.5
PM10

225-392
225-390

Impaction Discs for System
Select an impaction disc based on your application.
Recommended to Reduce Particle Bounce:
Replacement Pre-oiled Impaction Discs
porous plastic discs, 37 mm, ready to use, disposable,

pk/25

required for sampling, limited shelf-life

pk/50

225-395
225-395A

For Chemical Analysis of Larger Particles:
Quartz Filters,
37 mm, Tissuquartz, 432 μm thick, pk/25

225-1822

PTFE Filters,

§

37 mm, 2.0 μm, laminated PTFE support, pk/50

225-27-07

§ Back pressure on PTFE fi lters can vary within the same lot.
‡ Maximum operating temperature is 464 F (240 C) based on PMP support ring.

Accessories
Defender Calibrator, 300 to 30,000 ml/min,
includes lead-acid battery,
multi-plug charger (100-240 V), DryCal Pro Software, 39-inch (1-meter)
serial cable, and leak test caps; software requires Windows XP, Vista, or
Windows 7 and an RS-232 port or USB to RS-232 adapter

717-510H

Filter Cassette

225-395

Forceps, stainless steel

225-8371

Petri Dish Slide, for fi lter transport, pk/100

225-2-01

Glass Jars for Chemical Analysis

pk/8

pk/36

225-8376
225-8377

DataTrac for Leland Legacy Software includes software on CD and
USB cable

877-92

ORDERING INFORMATION

Description

Cat. No.

DPS System*

†#

includes a Leland Legacy Sample Pump with connection case and

charger (100-240 V), 2 external battery assemblies with adapters (packaged separately),
IMPACT sampling head, 2 fi lter cassettes, calibration adapter, rain cover for sampling
head, 25 disposable impaction discs,

fi lter cassette opener, tubing with quick-connect

fi tting, and mounting bracket, in a heavy-duty lockable carry case

PM10 Kit

100-3901

PM2.5 Kit

100-3903

* Provides data similar to data from Federal Reference Method samplers. The DPS System is not a

U.S. EPA reference or equivalent method for compliance sampling.

† Quantity discounts available
# DPS Systems contain Leland Legacy pumps with Li-Ion batteries and may be subject to special

shipping regulations.

∆ Limited

shelf-life

∞ Use in non-explosive environments only. Not intrinsically safe