Archive, Typical m90 classic, Fil filters ters ters ters ters – Ransburg M90 Handguns 77073, 77132 User Manual
Page 15: Line hose - fluid, Line hose - air

AH-99-01.3
M90 Handguns - Installation
1 1
1 1
1 1
1 1
1 1
>
Refer to the control unit service
manual for the circuit diagram and instruc-
tions to connect the control unit.
N O T E
N O T E
N O T E
N O T E
N O T E
>
The control unit MUST
MUST
MUST
MUST
MUST be located at
least three feet outside of the spray area.
Install units in accordance with the code
requirements. (See NFPA 33, 70, OSHA
and local codes.)
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
!!!!!
>
The Aviator power generator may be
located within the hazardous area.
N O T E
N O T E
N O T E
N O T E
N O T E
>
Verify that the gun handle is actually
grounded before operating it! This is done
with a fully connected and operational sys-
tem, by placing one lead of an ohmmeter to
the handle and the other to the building
electrical ground (cold water pipe, building
structure, steel, etc.). They should be
essentially zero.
>
If a greater reading is obtained, check
that the control unit is grounded. (See the
control unit manual for grounding procedure.)
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
!!!!!
>
The control unit MUST be located at
least three feet outside of the spray area.
Install units in accordance with the code
requirements. (See NFPA 33, 70, OSHA
and local codes.)
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
!!!!!
>
An air filter MUST
MUST
MUST
MUST
MUST be installed to pre-
vent contamination of the coating material by
the shaping air.
C A U T I O N
C A U T I O N
C A U T I O N
C A U T I O N
C A U T I O N
!!!!!
TYPICAL M90 CLASSIC
TYPICAL M90 CLASSIC
TYPICAL M90 CLASSIC
TYPICAL M90 CLASSIC
TYPICAL M90 CLASSIC
HANDGUN INST
HANDGUN INST
HANDGUN INST
HANDGUN INST
HANDGUN INSTALLA
ALLA
ALLA
ALLA
ALLATION
TION
TION
TION
TION
Connect the high voltage cable to the control
unit high voltage socket. Gently hand tighten
the cable retaining nut. Connect the other end
of the high voltage cable to the handgun, using
an Allen wrench to tighten the set screw in the
gun handle.
Connect the air hose to the inlet of the flow
switch on the control unit. Connect the outlet of
the flow switch with air hose to the handgun us-
ing a wrench.
The control unit may be connected through con-
duit with an explosion-proof switch on or near
the spray booth where it will be convenient to
the operator, or may be connected with a power
cord depending upon application requirement.
FIL
FIL
FIL
FIL
FILTERS
TERS
TERS
TERS
TERS
Install an air filter assembly onto the factory air.
LINE HOSE - FLUID
LINE HOSE - FLUID
LINE HOSE - FLUID
LINE HOSE - FLUID
LINE HOSE - FLUID
ITW Ransburg supplies a standard 36 foot
hose. Optional hose lengths of 50, 75, and 100
feet are available. ITW Ransburg offers this
hose ONLY as a complete assembly to ensure
that the hose is properly grounded at each end
fitting.
LINE HOSE - AIR
LINE HOSE - AIR
LINE HOSE - AIR
LINE HOSE - AIR
LINE HOSE - AIR
ITW Ransburg supplies a standard 36 foot
hose. Optional hose lengths of 50, 75, and 100
feet are available.
ARCHIVE