Archive – Ransburg REM Automatic Applicator 73499 User Manual
Page 33

AA-87-02.3
2 8
2 8
2 8
2 8
2 8
REM Automatic Applicator - Maintenance
4. Place the piston assembly [30] through [34] into
the valve chamber through bushing [28] and press
into place.
>
Be sure that o-ring [29] is in bushing
[28].
N O T E
N O T E
N O T E
N O T E
N O T E
5. Replace the barrel/cascade assembly (see
“Barrel/Cascade Assembly” in this section).
6. Replace the transformer assembly (see
“Transformer Assembly” in this section).
7. Place nut [34] on rod extension [22] 1/16-inch
from piston shaft [30].
8. Place nut [36] on rod extension [22] and secure
against nut [35] using appropriate wrenches. Be
sure to maintain the 1/16-inch spacing between
nut [35] and piston shaft [30].
9. Place springs [37] and [38] against piston [33]
and nut [36] and secure in place by screwing
piston housing [39] into the rear of the valve
housing.
Fluid T
Fluid T
Fluid T
Fluid T
Fluid Tube Removal
ube Removal
ube Removal
ube Removal
ube Removal
1. Remove fluid line and fluid filter [74] from fitting
[70].
2. Remove nut [71] from fitting [70].
3. Remove screw [56] from support bracket [52]
and [56] using 2.5mm Allen wrench.
4. Lossen nut [67] with an adjustable wrench. Grip
elbow connection [68] and pull straight down to
remove connector [67] from barrel [18] at [101].
5. Remove bracket [55] and [70] from fluid tube
[69].
6. Remove fluid tube [89] from elbow connector
[88].
7. Using fluid fitting tool [75], place over fluid
connector [85] and remove from elbow connection
[66]. Nut [67] will come off when fluid connector
[65] is removed from elbow connection [68].
>
Removing the connector [67] other than
straight down from barrel [18] may damage
or breach the connector [67]
C A U T I O N
C A U T I O N
C A U T I O N
C A U T I O N
C A U T I O N
!!!!!
>
This step may be eliminated if the Fluid
Connector [65] is NOT
NOT
NOT
NOT
NOT damaged.
N O T E
N O T E
N O T E
N O T E
N O T E
8. Replace o-rings [66], gasket [64] on any worn
or broken parts if required.
ARCHIVE