This information is intended ONLY to indicate the
general installation parameters of this product and,
where applicable, its working relationship to other
ITW Ransburg system components in typical use.
Each installation is unique and should be directed
by an ITW Ransburg representative or made from
the ITW Ransburg installion drawings provided
for your particular installation.

Safe Installation

Safe Installation

Safe Installation

Safe Installation

Safe Installation

• Ground the spray booth, the paint supply, and

the conveyor or work support.

• Ground all solvent and waste safety containers.

• Ground all work holders and hooks and keep

them free of paint.

• Ground the target object to a structural ground

and not back to the applicator system. See that
all target objects have a resistance to ground of
one megohm or LESS.

• See that all elements of the coating system are

correctly grounded, connected, and located.

• Position all ancillary non-approved electrical

apparatus, including but not limited to: high
voltage power supplies, fluid pumps, air com-
pressors, outside of the hazardous location.
(See the appropriate NFPA and/or OSHA
guidelines for your application and equipment.)

• Provide appropriate fire extinguishing equip-

ment.

• Provide conductive flooring in all spray areas.

9

9

9

9

9

REM Automatic Applicator - Installation

Low V

Low V

Low V

Low V

Low Voltage Cable

oltage Cable

oltage Cable

oltage Cable

oltage Cable

Connect the low voltage cable to the control unit
low voltage socket. Gently hand tighten the cable
retaining nut. The control unit MUST

MUST

MUST

MUST

MUST be

connected through conduit with an explosion-proof
switch on or near the spray booth where it will be
convenient to the operator.

W A R N I N G

W A R N I N G

W A R N I N G

W A R N I N G

W A R N I N G

!!!!!

>

Install and route the hoses and cable so they

are NOT

NOT

NOT

NOT

NOT exposed to temperature in excess of

120

° F and so that all hose and cable bends

are NOT LESS

NOT LESS

NOT LESS

NOT LESS

NOT LESS than a 6-inch (15cm) radius.

Failure to comply with these parameters could
cause equipment malfunctions that might
create HAZARDOUS CONDITIONS!

HAZARDOUS CONDITIONS!

HAZARDOUS CONDITIONS!

HAZARDOUS CONDITIONS!

HAZARDOUS CONDITIONS!

W A R N I N G

W A R N I N G

W A R N I N G

W A R N I N G

W A R N I N G

!!!!!

>

The control unit MUST

MUST

MUST

MUST

MUST be located outside of

the spray area. Install units in accordance with
the requirements of local regulations.

>

Refer to the current “Low Voltage

Control Unit” service manual for proper
installation.